CoChat

Component spatial pattern analysis of chemicals using terahertz spectroscopic imaging

Watanabe, Y., Kawase, K., Ikari, T., Ito, H., Ishikawa, Y., Minamide, H. · 2003 · Applied Physics Letters

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

We demonstrated the separation of the component spatial patterns of chemical samples in transillumination terahertz (THz) images using known spectral curves. The images and spectral data were measured between 1.3 and 1.8 THz, using a widely tunable coherent THz-wave parametric oscillator source. This method could be effective for analyzing spatial patterns and the concentrations of components with various chemical compositions.

Overview

Integrity signals

Registry

Crossref · 10.1063/1.1595132

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 10 references

Cited by

See all 140

Metadata

Authors
Watanabe, Y., Kawase, K., Ikari, T., Ito, H., Ishikawa, Y., & Minamide, H.
Affiliations
RIKEN (JP)
Venue
Applied Physics Letters
Published
2003-07-28
Volume
83
Issue
4
Pages
800-802
ISSN
  • 0003-6951 (ISSN-L)
  • 1077-3118
OpenAlex
W2069978221
Cited by
140
References
10
Citations by year
2025: 2 · 2023: 1 · 2022: 2 · 2021: 4 · 2020: 3 · 2019: 7 · 2018: 4 · 2017: 4 · 2016: 6 · 2015: 7 · 2014: 9 · 2013: 3 · 2012: 4
FWCI
9.70
Type
journal article
Language
en
Open access
closed
Locations
Applied Physics Letters (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
Keywords
terahertz spectroscopic imaging, transillumination imaging, compositional analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Component spatial pattern analysis of chemicals using terahertz spectroscopic imaging. https://app.cochat.ai/papers/10.1063/1.1595132
The paper
Watanabe, Y., Kawase, K., Ikari, T., Ito, H., Ishikawa, Y., & Minamide, H. (2003). Component spatial pattern analysis of chemicals using terahertz spectroscopic imaging. Applied Physics Letters. https://doi.org/10.1063/1.1595132

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.