The DOI matches its Crossref record.
Gaussian approximations of fluorescence microscope point-spread function models
Abstract
We comprehensively study the least-squares Gaussian approximations of the diffraction-limited 2D-3D paraxial-nonparaxial point-spread functions (PSFs) of the wide field fluorescence microscope (WFFM), the laser scanning confocal microscope (LSCM), and the disk scanning confocal microscope (DSCM). The PSFs are expressed using the Debye integral. Under an L(infinity) constraint imposing peak matching, optimal and near-optimal Gaussian parameters are derived for the PSFs. With an L1 constraint imposing energy conservation, an optimal Gaussian parameter is derived for the 2D paraxial WFFM PSF. We found that (1) the 2D approximations are all very accurate; (2) no accurate Gaussian approximation exists for 3D WFFM PSFs; and (3) with typical pinhole sizes, the 3D approximations are accurate for the DSCM and nearly perfect for the LSCM. All the Gaussian parameters derived in this study are in explicit analytical form, allowing their direct use in practical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Prions hijack tunnelling nanotubes for intercellular spread
Gousset, K., Schiff, E., Langevin, C., Marijanovic, Z., Caputo, A., Browman, D. T., Chenouard, N., de Chaumont, F., Martino, A., Enninga, J., et al. (2009) · Nature Cell Biology · doi:10.1038/ncb1841 · Cited by 615
Self-citationA review of progress in single particle tracking: from methods to biophysical insights
Manzo, C., & Garcia-Parajo, M. F. (2015) · Reports on Progress in Physics · doi:10.1088/0034-4885/78/12/124601 · Cited by 597
Single Particle Tracking: From Theory to Biophysical Applications
Shen, H., Tauzin, L. J., Baiyasi, R., Wang, W., Moringo, N., Shuang, B., & Landes, C. F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00815 · Cited by 536
Fast, single-molecule localization that achieves theoretically minimum uncertainty
Smith, C. S., Joseph, N., Rieger, B., & Lidke, K. A. (2010) · Nature Methods · doi:10.1038/nmeth.1449 · Cited by 522
Precisely and accurately localizing single emitters in fluorescence microscopy
Deschout, H., Zanacchi, F. C., Mlodzianoski, M., Diaspro, A., Bewersdorf, J., Hess, S. T., & Braeckmans, K. (2014) · Nature Methods · doi:10.1038/nmeth.2843 · Cited by 498
Metadata
- Authors
- Zhang, B., Zerubia, J., & Olivo-Marin, J.-C.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 2007-03-13
- Volume
- 46
- Issue
- 10
- Pages
- 1819
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2146404768
- Cited by
- 504
- References
- 0
- FWCI
- 9.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gaussian approximations of fluorescence microscope point-spread function models. https://app.cochat.ai/papers/10.1364/ao.46.001819
- The paper
- Zhang, B., Zerubia, J., & Olivo-Marin, J.-C. (2007). Gaussian approximations of fluorescence microscope point-spread function models. Applied Optics. https://doi.org/10.1364/ao.46.001819
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.