Direct and instantaneous observation of intravenously injected substances using intravital confocal micro-videography
Open accessThe DOI matches its Crossref record.
Abstract
We describe the development and application of intravital confocal micro-videography to visualize entrance, distribution, and clearance of drugs within various tissues and organs. We use a Nikon A1R confocal laser scanning microscope system attached to an upright ECLIPSE FN1. The Nikon A1R allows simultaneous four channel acquisition and speed of 30 frames per second while maintaining high resolution of 512 × 512 scanned points. The key techniques of our intravital imaging are (1) to present a flat and perpendicular surface to the objective lens, and (2) to expose the subject with little or no bleeding to facilitate optical access to multiple tissues and organs, and (3) to isolate the subject from the body movement without compressing the blood vessels, and (4) to insert a tail vein catheter for timed injection without moving the subject. Ear lobe dermis tissue was accessible without surgery. Liver, kidney, and subcutaneous tumor were accessed following exteriorization through skin incision. In order to image initial extravasations of compounds into tissue following intravenous injection, movie acquisition was initialized prior to drug administration. Our technique can serve as a powerful tool for investigating biological mechanisms and functions of intravenously injected drugs, with both spatial and temporal resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Accumulation of sub-100 nm polymeric micelles in poorly permeable tumours depends on size
Cabral, H., Matsumoto, Y., Mizuno, K., Chen, Q., Murakami, M., Kimura, M., Terada, Y., Kano, M. R., Miyazono, K., Uesaka, M., et al. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.166 · Cited by 2,429
Self-citationMiura, Y., Takenaka, T., Toh, K., Wu, S., Nishihara, H., Kano, M. R., Ino, Y., Nomoto, T., Matsumoto, Y., Koyama, H., et al. (2013) · ACS Nano · doi:10.1021/nn402662d · Cited by 454
Self-citationVascular bursts enhance permeability of tumour blood vessels and improve nanoparticle delivery
Matsumoto, Y., Nichols, J. W., Toh, K., Nomoto, T., Cabral, H., Miura, Y., Christie, R. J., Yamada, N., Ogura, T., Kano, M. R., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2015.342 · Cited by 412
Self-citationControlling the biodistribution and clearance of nanomedicines
Cabral, H., Li, J., Miyata, K., & Kataoka, K. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00138-1 · Cited by 303
“Although high-resolution intravital imaging (Box 2) is the gold standard for assessing intracellular distribution 327,328 , it is not suitable for the analysis of large libraries of nanocarriers and nanomedicines.”
Self-citationGlycaemic control boosts glucosylated nanocarrier crossing the BBB into the brain
Anraku, Y., Kuwahara, H., Fukusato, Y., Mizoguchi, A., Ishii, T., Nitta, K., Matsumoto, Y., Toh, K., Miyata, K., Uchida, S., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-00952-3 · Cited by 294
Self-citationSupramolecular Nanodevices: From Design Validation to Theranostic Nanomedicine
Cabral, H., Nishiyama, N., & Kataoka, K. (2011) · Accounts of Chemical Research · doi:10.1021/ar200094a · Cited by 292
Self-citationImproving Drug Potency and Efficacy by Nanocarrier-Mediated Subcellular Targeting
Murakami, M., Cabral, H., Matsumoto, Y., Wu, S., Kano, M. R., Yamori, T., Nishiyama, N., & Kataoka, K. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3001385 · Cited by 262
Self-citationStealth and pseudo-stealth nanocarriers
Wen, P., Ke, W., Dirisala, A., Toh, K., Tanaka, M., & Li, J. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.114895 · Cited by 201
Targeted Polymeric Micelles for siRNA Treatment of Experimental Cancer by Intravenous Injection
Christie, R. J., Matsumoto, Y., Miyata, K., Nomoto, T., Fukushima, S., Osada, K., Halnaut, J., Pittella, F., Kim, H. J., Nishiyama, N., et al. (2012) · ACS Nano · doi:10.1021/nn300942b · Cited by 193
“A detailed description of the microscope apparatus andmouse positioning for IVRTCLSM, aswell as examples of data workup showing ROIs, can be found in our previously published report.(35) Half-lives were calculated by plotting the natural log of intensity versus time for the initial period of signal decay (10 min for n…”
MethodSelf-citationZhao, M., Li, B., Wang, P., Lu, L., Zhang, Z., Liu, L., Wang, S., Li, D., Wang, R., & Zhang, F. (2018) · Advanced Materials · doi:10.1002/adma.201804982 · Cited by 182
Takeuchi, T., Kitayama, Y., Sasao, R., Yamada, T., Toh, K., Matsumoto, Y., & Kataoka, K. (2017) · Angewandte Chemie · doi:10.1002/ange.201700647 · Cited by 39
Self-citation
Metadata
- Authors
- Matsumoto, Y., Nomoto, T., Cabral, H., Matsumoto, Y., Watanabe, S., Christie, R. J., Miyata, K., Oba, M., Ogura, T., Yamasaki, Y., Nishiyama, N., Yamasoba, T., & Kataoka, K.
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2010-10-21
- Volume
- 1
- Issue
- 4
- Pages
- 1209
- ISSN
- 2156-7085 (ISSN-L)
- OpenAlex
- W2042389027
- Cited by
- 69
- References
- 0
- FWCI
- 3.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.