Online object oriented Monte Carlo computational tool for the needs of biomedical optics
Open accessThe DOI matches its Crossref record.
Abstract
Conceptual engineering design and optimization of laser-based imaging techniques and optical diagnostic systems used in the field of biomedical optics requires a clear understanding of the light-tissue interaction and peculiarities of localization of the detected optical radiation within the medium. The description of photon migration within the turbid tissue-like media is based on the concept of radiative transfer that forms a basis of Monte Carlo (MC) modeling. An opportunity of direct simulation of influence of structural variations of biological tissues on the probing light makes MC a primary tool for biomedical optics and optical engineering. Due to the diversity of optical modalities utilizing different properties of light and mechanisms of light-tissue interactions a new MC code is typically required to be developed for the particular diagnostic application. In current paper introducing an object oriented concept of MC modeling and utilizing modern web applications we present the generalized online computational tool suitable for the major applications in biophotonics. The computation is supported by NVIDEA CUDA Graphics Processing Unit providing acceleration of modeling up to 340 times.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Polarized light interaction with tissues
Tuchin, V. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071114 · Cited by 384
“2, 5, 13, 15, 59, 64, 68, 70, 73, 85, 89, 93, 94, 146, 147, 150, 151, and 153 – 160).”
BackgroundCell type specificity of neurovascular coupling in cerebral cortex
Uhlirova, H., Kılıç, K., Tian, P., Thunemann, M., Desjardins, M., Saisan, P. A., Sakadžić, S., Ness, T. V., Mateo, C., Cheng, Q., et al. (2016) · eLife · doi:10.7554/elife.14315 · Cited by 245
“…of the photon density in tissue produced by the OG beam (Figure 2B) was estimated using Monte Carlo simulation of photon migration in tissue (Doronin and Meglinski, 2011, 2012) assuming the following cortical gray matter optical parameters at 473 nm: absorption coefficient ma = 0.2 mm 1,…”
MethodResultInfluentialChatterjee, S., & Kyriacou, P. A. (2019) · Sensors · doi:10.3390/s19040789 · Cited by 86
“95 mm [13,31] and comprised six sublayers [23,26,32,33]: (1) stratum corneum; (2) epidermis; (3) papillary dermis; (4) upper blood net dermis; (5) reticular dermis and (6) deep blood net dermis.”
Background
Metadata
- Authors
- Doronin, A., & Meglinski, I.
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2011-07-29
- Volume
- 2
- Issue
- 9
- Pages
- 2461
- ISSN
- 2156-7085 (ISSN-L)
- OpenAlex
- W2142367776
- Cited by
- 162
- References
- 0
- FWCI
- 10.80
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Online object oriented Monte Carlo computational tool for the needs of biomedical optics. https://app.cochat.ai/papers/10.1364/boe.2.002461
- The paper
- Doronin, A., & Meglinski, I. (2011). Online object oriented Monte Carlo computational tool for the needs of biomedical optics. Biomedical Optics Express. https://doi.org/10.1364/boe.2.002461
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.