CoChat

Wearable respiration monitoring using an in-line few-mode fiber Mach-Zehnder interferometric sensor

Wang, Ruihang, Zhao, Jing, Sun, Ye, Yu, Hui, Zhou, Ning, Zhang, Hongxia, Jia, Dagong · 2020 · Biomedical Optics Express
Cited by 57

The DOI matches its Crossref record.

Abstract

Continuous respiratory monitoring is extensively important in clinical applications. To effectively assess respiration rate (RR), tidal volume (TV), and minute ventilation (MV), we propose and experimentally demonstrate a respiration monitoring system using an in-line few-mode fiber Mach-Zehnder interferometer (FMF-MZI), which is the first to introduce in-line MZI into an optimal wearable design for respiration rate and volume monitoring. The optimal linear region of the proposed sensor is analyzed and positioned by a flexible arch structure with curvature sensitivity up to 8.53 dB/m−1. Respiration monitoring results are in good agreement with a standard spirometer among different individuals. The difference in TV estimation is ± 0.2 L, and the overall error of MV estimation is less than 5%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/boe.376782

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 26

  1. Voscopoulos, 2014, J. Clin. Med. Res., 6, 209, 10.14740/jocmr1718w · DOI
  2. Chenivesse, 2014, Respir. Med., 108, 517, 10.1016/j.rmed.2013.10.024 · DOI · Paper page
  3. Bonsignore, 1994, Eur. Respir. J., 7, 786, 10.1183/09031936.94.07040786 · DOI · Paper page
  4. Joshi, 1988, Surv. Anesthesiol., 32, 121, 10.1097/00132586-198804000-00050 · doi:10.1097/00132586-198804000-00050
  5. Fathizadeh, 2004, Crit. Care Med., 32, 1300, 10.1097/01.CCM.0000127776.78490.E4 · DOI
  6. Semmes, 1985, Chest, 87, 577, 10.1378/chest.87.5.577 · DOI
  7. Kermit, 2000, Pattern Recognit. Lett., 21, 277, 10.1016/S0167-8655(99)00157-9 · DOI
  8. Leonard, 2003, Emerg. Med. J., 20, 524, 10.1136/emj.20.6.524 · DOI · Paper page
  9. Sayadi, 2014, Am. J. Physiol.-Heart Circul. Physiol., 307, H426, 10.1152/ajpheart.00038.2014 · DOI
  10. Lafortuna, 1995, Eur. J. Appl. Physiol. Occup. Physiol., 71, 259, 10.1007/BF00854988 · doi:10.1007/bf00854988
  11. Aoki, 2018, Sports, 6, 23, 10.3390/sports6010023 · doi:10.3390/sports6010023
  12. Transue, 2016, Real-time tidal volume estimation using iso-surface reconstruction, 10.1109/CHASE.2016.72 · DOI
  13. Reyes, 2017, IEEE J. Biomed. Health Inform., 21, 764, 10.1109/JBHI.2016.2532876 · DOI
  14. Dziuda, 2015, J. Biomed. Opt., 20, 010901, 10.1117/1.JBO.20.1.010901 · DOI · Paper page
  15. Fernandes, 2014, IEEE J. Sel. Top. Quantum Electron., 20, 112, 10.1109/JSTQE.2013.2294455 · DOI
  16. Roriz, 2013, J. Biomed. Opt., 18, 050903, 10.1117/1.JBO.18.5.050903 · DOI · Paper page
  17. Wo, 2014, J. Biomed. Opt., 19, 017003, 10.1117/1.JBO.19.1.017003 · DOI
  18. Elsarnagawy, 2015, Sens. Lett., 13, 48, 10.1166/sl.2015.3407 · DOI
  19. Yang, 2015, IEEE Sens. J., 15, 757, 10.1109/JSEN.2014.2353640 · DOI · Paper page
  20. Hu, 2016, Sens. Actuators, A, 251, 126, 10.1016/j.sna.2016.10.013 · DOI
  21. Di, 2017, J. Mod. Opt., 64, 639, 10.1080/09500340.2016.1255367 · doi:10.1080/09500340.2016.1255367
  22. Petrović, 2014, Biomed. Opt. Express, 5, 1136, 10.1364/BOE.5.001136 · doi:10.1364/boe.5.001136
  23. Wang, 2016, IEEE Photonics Technol. Lett., 28, 71, 10.1109/LPT.2015.2483518 · DOI
  24. Wang, 2011, Opt. Lett., 36, 558, 10.1364/OL.36.000558 · doi:10.1364/ol.36.000558
  25. Kaneko, 2012, Respir. Care, 57, 1442, 10.4187/respcare.01655 · doi:10.4187/respcare.01655
  26. Konno, 1967, J. Appl. Physiol., 22, 407, 10.1152/jappl.1967.22.3.407 · DOI · Paper page

Cited by

Metadata

Authors
Wang, R., Zhao, J., Sun, Y., Yu, H., Zhou, N., Zhang, H., & Jia, D.
Venue
Biomedical Optics Express
Published
2019-12-18
Volume
11
Issue
1
Pages
316
ISSN
2156-7085
Cited by
57
References
0
Language
en
Licence
Funders
National Natural Science Foundation of China (61875152, U1813207)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.