Estimation of core body temperature by near-infrared imaging of vein diameter change in the dorsal hand
Open accessAbstract
Core body temperature (Tcore) is a key indicator of personal thermal comfort and serves as a monitor of thermal strain. Multi-parametric sensors are not practical for estimating core temperature because they require long data collection times and a wide variety of settings. This study introduces dorsal hand vein dynamics as a novel indicator along with heart rate (HR) and dorsal hand skin temperature (Thand) for predicting Tcore during rest following Tcore elevation. Twelve healthy males aged 27 ± 9 years old participated in the experiment. The experimental procedure consisted of a 10-min rest followed by 60 min of passive heat stress induced by leg immersion in hot water at 42°C and a 40-min thermal relaxation period after the legs were removed from the water. A near-infrared (NIR) imaging system was configured to monitor the dorsal hand veins during the entire experimental session. The values of HR, Thand, and Tcore were continuously monitored while the ambient temperature and relative humidity (RH) were maintained in a climate chamber at 20°C and 50%, respectively. Our selected predictor parameters demonstrated similar patterns in the Tcore such that the value increased as a result of passive heat stress and decreased in the thermal relaxation phase. The experimental data were divided into two phases: thermal stress and relaxation. At the resting condition, inclusion of the hand vein diameter (VD) improved the multiple linear regression value (R2) about 26%. At the relaxation phase, however, training regressions R2 = 0.68 and R2 = 0.94 were observed in the regression model with and without considering VD, respectively. The test regression value of R2 = 0.88 and the root mean square error (RMSE) of 0.18°C showed good agreement with the predicted values. These findings demonstrate acceptable validity of the non-invasive Tcore estimation at the resting condition. In particular, the inclusion of VD as a predictor in the regression analysis increases the prediction accuracy with a lower RMSE value.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Indirect core body temperature evaluation can achieve a high accuracy of ±0.03 °C.
“From these data, the internal core body temperature is evaluated with a high accuracy of ±0.03 °C [129,140,146,147,148,149].”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [147]
The citation lists haven’t been fetched yet
References 32 · Cited by 10
- Authors
- Shourav, M. K., Salsabila, S., Lee, J.-Y., & Kim, J. K.
- Affiliations
- Kookmin University (KR)
- Seoul National University (KR)
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2021-07-06
- Volume
- 12
- Issue
- 8
- Pages
- 4700
- ISSN
- 2156-7085 (ISSN-L)
- PMC
- PMC8407806
- OpenAlex
- W3175311185
- Cited by
- 10
- References
- 32
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 2 · 2023: 3 · 2022: 1 · 2021: 1
- FWCI
- 1.10
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Biomedical Optics Express (publishedVersion)
- PubMed Central (publishedVersion, other-oa)
- PubMed (publishedVersion)
- Seoul National University Open Repository (Seoul National University) (submittedVersion)
- Funders
- Korea Evaluation Institute of Industrial Technology (20011377)
- National Research Foundation of Korea (NRF-2019R1A2C2006961, NRF-2019R1A2C2088973)
- Topics
- Health Sciences › Medicine › Physiology › Thermoregulation and physiological responses
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
- Keywords
- core body temperature estimation, near-infrared imaging, passive heat stress, thermal relaxation, heart rate, skin temperature, non-invasive temperature measurement, multiple linear regression, thermal comfort monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›