Cited by 10Thermoregulation and physiological responsesInfrared Thermography in MedicineCardiovascular and exercise physiology

Estimation of core body temperature by near-infrared imaging of vein diameter change in the dorsal hand

Open access
Shourav, Mohiuddin Khan, Salsabila, Syifa, Lee, Joo-Young, Kim, Jung Kyung·2021·Biomedical Optics Express

Abstract

Core body temperature (Tcore) is a key indicator of personal thermal comfort and serves as a monitor of thermal strain. Multi-parametric sensors are not practical for estimating core temperature because they require long data collection times and a wide variety of settings. This study introduces dorsal hand vein dynamics as a novel indicator along with heart rate (HR) and dorsal hand skin temperature (Thand) for predicting Tcore during rest following Tcore elevation. Twelve healthy males aged 27 ± 9 years old participated in the experiment. The experimental procedure consisted of a 10-min rest followed by 60 min of passive heat stress induced by leg immersion in hot water at 42°C and a 40-min thermal relaxation period after the legs were removed from the water. A near-infrared (NIR) imaging system was configured to monitor the dorsal hand veins during the entire experimental session. The values of HR, Thand, and Tcore were continuously monitored while the ambient temperature and relative humidity (RH) were maintained in a climate chamber at 20°C and 50%, respectively. Our selected predictor parameters demonstrated similar patterns in the Tcore such that the value increased as a result of passive heat stress and decreased in the thermal relaxation phase. The experimental data were divided into two phases: thermal stress and relaxation. At the resting condition, inclusion of the hand vein diameter (VD) improved the multiple linear regression value (R2) about 26%. At the relaxation phase, however, training regressions R2 = 0.68 and R2 = 0.94 were observed in the regression model with and without considering VD, respectively. The test regression value of R2 = 0.88 and the root mean square error (RMSE) of 0.18°C showed good agreement with the predicted values. These findings demonstrate acceptable validity of the non-invasive Tcore estimation at the resting condition. In particular, the inclusion of VD as a predictor in the regression analysis increases the prediction accuracy with a lower RMSE value.

Integrity signals

Registry

Crossref · 10.1364/boe.431534

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Indirect core body temperature evaluation can achieve a high accuracy of ±0.03 °C.

    “From these data, the internal core body temperature is evaluated with a high accuracy of ±0.03 °C [129,140,146,147,148,149].”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [147]

The citation lists haven’t been fetched yet

References 32 · Cited by 10

Authors
Shourav, M. K., Salsabila, S., Lee, J.-Y., & Kim, J. K.
Affiliations
  • Kookmin University (KR)
  • Seoul National University (KR)
Venue
Biomedical Optics Express
Published
2021-07-06
Volume
12
Issue
8
Pages
4700
ISSN
2156-7085 (ISSN-L)
OpenAlex
W3175311185
Cited by
10
References
32
Citations by year
2026: 1 · 2025: 2 · 2024: 2 · 2023: 3 · 2022: 1 · 2021: 1
FWCI
1.10
Type
journal article
Language
en
Open access
Locations
  • Biomedical Optics Express (publishedVersion)
  • PubMed Central (publishedVersion, other-oa)
  • PubMed (publishedVersion)
  • Seoul National University Open Repository (Seoul National University) (submittedVersion)
Funders
  • Korea Evaluation Institute of Industrial Technology (20011377)
  • National Research Foundation of Korea (NRF-2019R1A2C2006961, NRF-2019R1A2C2088973)
Topics
  • Health Sciences › Medicine › Physiology › Thermoregulation and physiological responses
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
Keywords
core body temperature estimation, near-infrared imaging, passive heat stress, thermal relaxation, heart rate, skin temperature, non-invasive temperature measurement, multiple linear regression, thermal comfort monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review