Development of a luminous textile for reflective pulse oximetry measurements
Open accessThe DOI matches its Crossref record.
Abstract
In this paper, a textile-based sensing principle for long term photopletysmography (PPG) monitoring is presented. Optical fibers were embroidered into textiles such that out-coupling and in-coupling of light was possible. The "light-in light-out" properties of the textile enabled the spectroscopic characterization of human tissue. For the optimization of the textile sensor, three different carrier fabrics and different fiber modifications were compared. The sample with best light coupling efficiency was successfully used to measure heart rate and SpO2 values of a subject. The latter was determined by using a modified Beer-Lambert law and measuring the light attenuation at two different wavelengths (632 nm and 894 nm). Moreover, the system was adapted to work in reflection mode which makes the sensor more versatile. The measurements were additionally compared with commercially available system and showed good correlation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wearable health devices-vital sign monitoring, systems and technologies
Dias, D., & Paulo Silva Cunha, J. (2018) · Sensors · doi:10.3390/s18082414 · Cited by 919
“[44] developed this new textile technology capable to analyze different depths of tissue, where both light-source and detectors are made using optical fibers.”
BackgroundSmart textiles for personalized healthcare
Libanori, A., Chen, G., Zhao, X., Zhou, Y., & Chen, J. (2022) · Nature Electronics · doi:10.1038/s41928-022-00723-z · Cited by 739
Electronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Battery-free, stretchable optoelectronic systems for wireless optical characterization of the skin
Kim, J., Salvatore, G. A., Araki, H., Chiarelli, A. M., Xie, Z., Banks, A., Sheng, X., Liu, Y., Lee, J. W., Jang, K.-I., et al. (2016) · Science Advances · doi:10.1126/sciadv.1600418 · Cited by 403
Grassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
“for monitoring arterial O2 saturation (measured by pulse oximetry) and muscle oxygenation changes.(208) Wearable wireless fingertip pulse oximetry devices, for arterial O2 saturation measurement, are already available for smart phones.”
Background
Metadata
- Authors
- Krehel, M., Wolf, M., Boesel, L. F., Rossi, R. M., Bona, G.-L., & Scherer, L. J.
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2014-07-09
- Volume
- 5
- Issue
- 8
- Pages
- 2537
- ISSN
- 2156-7085 (ISSN-L)
- OpenAlex
- W2028743241
- Cited by
- 66
- References
- 0
- FWCI
- 2.81
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a luminous textile for reflective pulse oximetry measurements. https://app.cochat.ai/papers/10.1364/boe.5.002537
- The paper
- Krehel, M., Wolf, M., Boesel, L. F., Rossi, R. M., Bona, G.-L., & Scherer, L. J. (2014). Development of a luminous textile for reflective pulse oximetry measurements. Biomedical Optics Express. https://doi.org/10.1364/boe.5.002537
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.