Broadband absorption and reduced scattering spectra of in-vivo skin can be noninvasively determined using δ-P_1 approximation based spectral analysis
Open accessAbstract
Previously, we revealed that a linear gradient line source illumination (LGLSI) geometry could work with advanced diffusion models to recover the sample optical properties at wavelengths where sample absorption and reduced scattering were comparable. In this study, we employed the LGLSI geometry with a broadband light source and utilized the spectral analysis to determine the broadband absorption and scattering spectra of turbid samples in the wavelength range from 650 to 1350 nm. The performance of the LGLSI δ-P1 diffusion model based spectral analysis was evaluated using liquid phantoms, and it was found that the sample optical properties could be properly recovered even at wavelengths above 1000 nm where μs' to μa ratios were in the range between 1 to 20. Finally, we will demonstrate the use of our system for recovering the 650 to 1350 nm absorption and scattering spectra of in-vivo human skin. We expect this system can be applied to study deep vessel dilation induced hemoglobin concentration variation and determine the water and lipid concentrations of in-vivo skin in clinical settings in the future.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Measured reduced scattering coefficients have up to 10-fold variability using DRS at 700 nm, ranging from 0.184 mm-1 to 2.19 mm-1.
“Similarly, measured reduced scattering coefficients have up to 10-fold variability using DRS at this wavelength, ranging from 0.184 mm-1 to 2.19 mm-1 [55,57,60,61].”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [60]
Peaks in absorbance were observed at 970 nm and 1150 nm - 1200 nm corresponding with water absorption.
“Peaks in absorbance were observed at 970 nm and 1150 nm - 1200 nm corresponding with water absorption.”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [60]
The citation lists haven’t been fetched yet
References 25 · Cited by 8
- Authors
- Hung, C.-H., Chou, T.-C., Hsu, C.-K., & Tseng, S.-H.
- Affiliations
- National Cheng Kung University (TW)
- National Cheng Kung University Hospital (TW)
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2015-01-09
- Volume
- 6
- Issue
- 2
- Pages
- 443
- ISSN
- 2156-7085 (ISSN-L)
- PMC
- PMC4354575
- OpenAlex
- W1978806174
- Cited by
- 8
- References
- 25
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 1 · 2020: 1 · 2018: 2 · 2015: 1
- FWCI
- 0.81
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Biomedical Optics Express (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Council Taiwan (NSC) (NSC 102-2221-E-006-248-MY2)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
- Keywords
- in vivo skin, spectral analysis, broadband light source, turbid samples, liquid phantom, tissue optical properties, hemoglobin levels
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review