Metal-Semiconductor-Metal Near Infrared Light Detector Based on Epitaxial Ge on Si
The DOI matches its Crossref record.
Abstract
Due to the ever growing use of optical fibers in communications, for both long distances and local area networks, there is an increasing effort toward the realization of high speed and high efficiency optical detectors, operating in the low-absorption regions (1.3-1.55µm) of silica fibers. Although III-V semiconductors provide high detection efficiency in the range of interest, incorporating them in the well-established Si-based very large scale integration technology is difficult and expensive[1]. Ge-on-Si structures represents a viable alternative solution for near infrared photodetection, owing to their narrow band gap and full compatibility with silicon technologies. Pure germanium, indeed, represents the best candidate for absorbing in 1.3-1.55 µm photodetectors, due to its direct bandgap of 0.85eV. However, owing to the high lattice mismatch with Si, it is not easy to obtain Ge films with characteristics suitable for integrated electronics: thickness (efficiency of the device), flatness (realization of submicron lithography), defect-free structure (high-speed).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Planar-integrated single-crystalline perovskite photodetectors
Saidaminov, M. I., Adinolfi, V., Comin, R., Abdelhady, A. L., Peng, W., Dursun, I., Yuan, M., Hoogland, S., Sargent, E. H., & Bakr, O. M. (2015) · Nature Communications · doi:10.1038/ncomms9724 · Cited by 734
High-quality Ge epilayers on Si with low threading-dislocation densities
Luan, H.-C., Lim, D. R., Lee, K. K., Chen, K. M., Sandland, J. G., Wada, K., & Kimerling, L. C. (1999) · Applied Physics Letters · doi:10.1063/1.125187 · Cited by 679
Zeng, L.-H., Wang, M.-Z., Hu, H., Nie, B., Yu, Y.-Q., Wu, C.-Y., Wang, L., Hu, J.-G., Xie, C., Liang, F.-X., et al. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am4026505 · Cited by 411
Si–Ge–Sn alloys: From growth to applications
Wirths, S., Buca, D., & Mantl, S. (2016) · Progress in Crystal Growth and Characterization of Materials · doi:10.1016/j.pcrysgrow.2015.11.001 · Cited by 282
Liow, T.-Y., Ang, K.-W., Fang, Q., Song, J.-F., Xiong, Y.-Z., Yu, M.-B., Lo, G.-Q., & Kwong, D.-L. (2010) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2009.2028657 · Cited by 275
Ge-Photodetectors for Si-Based Optoelectronic Integration
Wang, J., & Lee, S. (2011) · Sensors · doi:10.3390/s110100696 · Cited by 245
Efficient high-speed near-infrared Ge photodetectors integrated on Si substrates
Colace, L., Masini, G., Assanto, G., Luan, H.-C., Wada, K., & Kimerling, L. C. (2000) · Applied Physics Letters · doi:10.1063/1.125993 · Cited by 235
Self-citationHartmann, J. M., Abbadie, A., Papon, A. M., Holliger, P., Rolland, G., Billon, T., Fédéli, J. M., Rouvière, M., Vivien, L., & Laval, S. (2004) · Journal of Applied Physics · doi:10.1063/1.1699524 · Cited by 224
Graphene/Semiconductor Hybrid Heterostructures for Optoelectronic Device Applications
Xie, C., Wang, Y., Zhang, Z.-X., Wang, D., & Luo, L.-B. (2018) · Nano Today · doi:10.1016/j.nantod.2018.02.009 · Cited by 216
Germanium‐based integrated photonics from near‐ to mid‐infrared applications
Marris‐Morini, D., Vakarin, V., Ramirez, J. M., Liu, Q., Ballabio, A., Frigerio, J., Montesinos, M., Alonso‐Ramos, C., Le Roux, X., Serna, S., et al. (2017) · Nanophotonics · doi:10.1515/nanoph-2018-0113 · Cited by 205
High performance germanium-on-silicon detectors for optical communications
Famà, S., Colace, L., Masini, G., Assanto, G., & Luan, H.-C. (2002) · Applied Physics Letters · doi:10.1063/1.1496492 · Cited by 168
Self-citationGermanium photodetector with 60 GHz bandwidth using inductive gain peaking
Novack, A., Gould, M., Yang, Y., Xuan, Z., Streshinsky, M., Liu, Y., Capellini, G., Lim, A. E.-J., Lo, G.-Q., Baehr-Jones, T., et al. (2013) · Optics Express · doi:10.1364/oe.21.028387 · Cited by 165
Self-citationGeSn p-i-n waveguide photodetectors on silicon substrates
Peng, Y.-H., Cheng, H. H., Mashanov, V. I., & Chang, G.-E. (2014) · Applied Physics Letters · doi:10.1063/1.4903881 · Cited by 98
High-Volume Manufacturing Platform for Silicon Photonics
Pinguet, T., Denton, S., Gloeckner, S., Mack, M., Masini, G., Mekis, A., Pang, S., Peterson, M., Sahni, S., & Dobbelaere, P. D. (2018) · Proceedings of the IEEE · doi:10.1109/jproc.2018.2859198 · Cited by 48
Self-citation
Metadata
- Authors
- Colace, L., Masini, G., Galluzzi, F., Assanto, G., Capellini, G., Di Gaspare, L., Palange, E., & Evangelisti, F.
- Venue
- Conference on Lasers and Electro-Optics-Europe
- Publisher
- Optica Publishing Group
- Published
- 1998
- Volume
- 31
- Pages
- CTuL5
- OpenAlex
- W4320805313
- Cited by
- 204
- References
- 0
- FWCI
- 19.36
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.