The DOI matches its Crossref record.
Visual Sensitivities to Color Differences in Daylight*
Abstract
An apparatus is described which facilitates the presentation of pairs of variable colors without variation of luminance. With this instrument, various criteria of visual sensitivity to color difference have been investigated. The standard deviation of color matching was finally adopted as the most reproducible criterion. The test field was two degrees in diameter, divided by a vertical biprism edge, and was viewed centrally with a surrounding field of forty-two degrees diameter uniformly illuminated so as to have a chromaticity similar to that of the I.C.I. Standard Illuminant C (average daylight). The luminance of the test field was maintained constant at 15 millilamberts, and the surrounding field was 7.5 millilamberts. These fields were viewed monocularly through an artificial pupil, 2.6 mm in diameter. Over twenty-five thousand trials at color matching have been recorded for a single observer, and the readings are analyzed in detail and compared with previously available data. The standard deviations of the trials are represented in terms of distance in the standard 1931 I.C.I. chromaticity diagram. These increments of distance are represented as functions of position alongstraight lines in the chromaticity diagram, and also as functions of direction of departure from points representing certain standard chromaticities. Such representations are simpler than the traditional representations of wave-length thresholds and purity thresholds as functions of wave-length, and the accuracy of the representations is improved by this simplicity. Chromaticity discrimination for non-spectral colors is represented simultaneously and on the same basis as for spectral colors. Small, equally noticeable chromaticity differences are represented for all chromaticities and for all kinds of variations by the lengths of the radii of a family of ellipses drawn on the standard chromaticity diagram. These ellipses cannot be transformed into equal-sized circles by any projective transformation of the standard chromaticity diagram. The consistency of these data with the results of other investigators is exhibited in terms of the noticeabilities of wave-length differences in the spectrum and of the noticeabilities of purity differences from a neutral stimulus, as functions of dominant wave-length.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
What attributes guide the deployment of visual attention and how do they do it?
Wolfe, J. M., & Horowitz, T. S. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1411 · Cited by 1,766
Color and spatial structure in natural scenes
Burton, G. J., & Moorhead, I. R. (1987) · Applied Optics · doi:10.1364/ao.26.000157 · Cited by 499
Sharma, G., & Trussell, H. J. (1997) · IEEE Transactions on Image Processing · doi:10.1109/83.597268 · Cited by 440
Evaluation of Uniform Color Spaces Developed after the Adoption of CIELAB and CIELUV
Mahy, M., Van Eycken, L., & Oosterlinck, A. (1994) · Color Research & Application · doi:10.1111/j.1520-6378.1994.tb00070.x · Cited by 377
Colour thresholds and receptor noise: behaviour and physiology compared
Vorobyev, M., Brandt, R., Peitsch, D., Laughlin, S. B., & Menzel, R. (2001) · Vision Research · doi:10.1016/s0042-6989(00)00288-1 · Cited by 309
Metadata
- Authors
- MacAdam, D. L.
- Venue
- Journal of the Optical Society of America
- Publisher
- Optica Publishing Group
- Published
- 1942-05-01
- Volume
- 32
- Issue
- 5
- Pages
- 247
- ISSN
- 0030-3941 (ISSN-L)
- OpenAlex
- W2003577166
- Cited by
- 1,141
- References
- 0
- FWCI
- 40.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Visual Sensitivities to Color Differences in Daylight*. https://app.cochat.ai/papers/10.1364/josa.32.000247
- The paper
- MacAdam, D. L. (1942). Visual Sensitivities to Color Differences in Daylight*. Journal of the Optical Society of America. https://doi.org/10.1364/josa.32.000247
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.