The Sensitivity of the Human Eye to Infra-Red Radiation
The DOI matches its Crossref record.
Abstract
The spectral sensitivity of human vision has been measured in the near infra-red, in two areas of the dark adapted eye: the central fovea (cones) to 1000 mμ, and a peripheral area, in which the responses are primarily caused by rods, to 1050 mμ. In both cases the estimates of spectral sensitivity are based upon determinations of the visual thresholds for radiation passing through a series of infra-red filters. By successive approximation, sensitivity functions were chosen which were consistent with the observed thresholds.The spectral sensitivity of the fovea determined in this way is consistent with previous measurements of Goodeve on the unfixated eye. At wave-lengths beyond 800 mμ the periphery becomes appreciably more sensitive than the fovea. This tendency increases at longer wave-lengths, so that at the longest wave-lengths studied, the radiation appeared colorless at the threshold and stimulated only rods.Lengthening the exposure time increases the sensitivity of the peripheral retina relative to the fovea. Our measurements involved exposures of 1 second and fields subtending a visual angle of 1 degree. With shorter exposures or smaller fields the fovea is favored, so that under such circumstances the fovea may become more sensitive than the periphery well into the infra-red.At 1050 mμ the sensitivity of the peripheral retina is only 3×10−13 times its maximum value at 505 mμ. A computation shows that by 1150 or 1200 mμ radiation should be more readily felt as heat by the skin than seen as light by the eye.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
In search of the visual pigment template
GOVARDOVSKII, V. I., FYHRQUIST, N., REUTER, T., KUZMIN, D. G., & DONNER, K. (2000) · Visual Neuroscience · doi:10.1017/s0952523800174036 · Cited by 1,055
Spectral sensitivity of cones of the monkey Macaca fascicularis
Baylor, D. A., Nunn, B. J., & Schnapf, J. L. (1987) · The Journal of Physiology · doi:10.1113/jphysiol.1987.sp016691 · Cited by 344
Spectral sensitivity of human cone photoreceptors
Schnapf, J. L., Kraft, T. W., & Baylor, D. A. (1987) · Nature · doi:10.1038/325439a0 · Cited by 342
WHY RED FLOWERS ARE NOT INVISIBLE TO BEES
Chittka, L., & Waser, N. M. (1997) · Israel Journal of Plant Sciences · doi:10.1080/07929978.1997.10676682 · Cited by 272
Photoreceptor spectral sensitivities: Common shape in the long-wavelength region
Lamb, T. D. (1995) · Vision Research · doi:10.1016/0042-6989(95)00114-f · Cited by 179
Metadata
- Authors
- GRIFFIN, D. R., HUBBARD, R., & WALD, G.
- Venue
- Journal of the Optical Society of America
- Publisher
- Optica Publishing Group
- Published
- 1947-07-01
- Volume
- 37
- Issue
- 7
- Pages
- 546
- ISSN
- 0030-3941 (ISSN-L)
- OpenAlex
- W1963661558
- Cited by
- 92
- References
- 0
- FWCI
- 10.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Sensitivity of the Human Eye to Infra-Red Radiation. https://app.cochat.ai/papers/10.1364/josa.37.000546
- The paper
- GRIFFIN, D. R., HUBBARD, R., & WALD, G. (1947). The Sensitivity of the Human Eye to Infra-Red Radiation. Journal of the Optical Society of America. https://doi.org/10.1364/josa.37.000546
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.