Axicons and Their Uses
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The most common axicon is a flat cone. A small source of light on the axis of the cone is imaged into a line along a portion of the axis. In lenses the spot diagram has been useful in evaluating image quality. In axicons a corresponding line diagram where lines take the place of dots is useful. In general, axicon instruments correspond to the usual optical instruments. For example, an axicon may be used as an objective to form a telescope. The resulting axicon telescope may be used in aligning machinery such as paper mills. Similarly, an axicon autocollimator may be used to precisely set mirrors perpendicular to a line. One form of axicon microscope has been tried out for the special purpose of locating the position of shiny surfaces without touching them. A most useful form of optical aligner is the reflection cone axicon. It is used as a straight edge. One example is a reflecting cone of 6 in. diam and maximum range of 40 ft with precision of 5 or 6 wavelengths over the entire range. Another example is a 5 in. diam cone with a range of 10 ft and precisions of about 1 wavelength. In this case the use of a suitable radius for the reflecting surface had the effect of making the image brightness substantially uniform over the 10 ft range. Photo cell pickup has been shown to be successful with very high precisions of setting. This opens the way for automatic machine guiding to very high precisions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Axicon: A New Type of Optical Element
McLeod, J. H. (1954) · Journal of the Optical Society of America · doi:10.1364/josa.44.000592 · Cited by 970
Self-citation
Cited by
Aieta, F., Genevet, P., Kats, M. A., Yu, N., Blanchard, R., Gaburro, Z., & Capasso, F. (2012) · Nano Letters · doi:10.1021/nl302516v · Cited by 1,801
Zou, X., Zheng, G., Yuan, Q., Zang, W., Chen, R., Li, T., Li, L., Wang, S., Wang, Z., & Zhu, S. (2020) · PhotoniX · doi:10.1186/s43074-020-00007-9 · Cited by 189
High-performance axicon lenses based on high-contrast, multilayer gratings
Doshay, S., Sell, D., Yang, J., Yang, R., & Fan, J. A. (2018) · APL Photonics · doi:10.1063/1.5009760 · Cited by 9
Metadata
- Authors
- McLeod, J. H.
- Venue
- Journal of the Optical Society of America
- Publisher
- Optica Publishing Group
- Published
- 1960-02-01
- Volume
- 50
- Issue
- 2
- Pages
- 166
- ISSN
- 0030-3941 (ISSN-L)
- OpenAlex
- W2040701347
- Cited by
- 179
- References
- 1
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Axicons and Their Uses. https://app.cochat.ai/papers/10.1364/josa.50.000166
- The paper
- McLeod, J. H. (1960). Axicons and Their Uses. Journal of the Optical Society of America. https://doi.org/10.1364/josa.50.000166
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.