Cited by 237Corneal surgery and disordersOptical Polarization and EllipsometrySurface Roughness and Optical Measurements

Light scattering in the cornea

Hart, Robert W., Farrell, Richard A.·1969·Journal of the Optical Society of America

Abstract

The physical basis for the transparency of the cornea to visible light is investigated theoretically in terms of the molecular structure as depicted by electron microscopy. Electron micrographs show that the major portion of the cornea contains long cylindrical fibrils arranged in a quasi-random fashion, with local order extending over distances comparable to the wavelength of light. Heretofore, the generally accepted explanation of transparency has been in terms of a supposed crystalline arrangement of the fibrils, because this was the only distribution that could ensure transparency on a simple theoretical basis. Thus, the non-crystalline structure shown by the electron microscope has been widely regarded as an artifact due to the fixation procedure. In the present work, the light scattering from the fibrils is formulated in terms of their radial distribution function, which is determined by numerical analysis of electron micrographs. Comparison of theoretical results and experimental values for transmittance through rabbit cornea shows that the quasi-regular quasi-random structure revealed by the electron microscope is not in conflict with transparency.

Integrity signals

Registry

Crossref · 10.1364/josa.59.000766

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The basic ultrastructure of the cornea had been described about 50 years ago and the principles behind corneal transparency were elucidated.

    “About 50 years ago the basic ultrastructure had been described (Jakus, 1962) and the principles behind corneal transparency finally elucidated (Maurice, 1957, Hart and Farrell, 1969, Benedek, 1971)”

    From Corneal structure and transparency (2015) · cites this paper as Hart and Farrell, 1969

  • Collagen fibrils within the cornea are narrower than in many other connective tissues, and this is an important factor for transparency, which is a function of the diameter.

    “Collagen fibrils within the cornea are narrower than in many other connective tissues and this is an important factor for transparency, which is a function of the diameter (Hart and Farrell, 1969).”

    From Corneal structure and transparency (2015) · cites this paper as Hart and Farrell, 1969

  • Models by Maurice (1962) and Hart and Farrell (1969) proposed that collagen fibrils in the corneal stroma are connected to six adjacent fibrils by proteoglycans at regular axial intervals, and that the defined lengths of the proteoglycans force the fibrils onto a perfect hexagonal lattice, guaranteeing corneal transparency.

    “The models they proposed were based essentially on the collagen fibrils in the corneal stroma being connected to six adjacent fibrils by proteoglycans at regular axial intervals. The defined lengths of the proteoglycans would force the fibrils on a perfect hexagonal lattice, which would guarantee corneal transparency.”

    From Corneal structure and transparency (2015) · cites this paper as Hart and Farrell in 1969

Cited by

Sorted by citations

Authors
Hart, R. W., & Farrell, R. A.
Affiliations
Johns Hopkins University (US)
Venue
Journal of the Optical Society of America
Published
1969-06-01
Volume
59
Issue
6
Pages
766
ISSN
0030-3941 (ISSN-L)
OpenAlex
W2084861664
Cited by
237
References
0
Citations by year
2026: 2 · 2025: 1 · 2024: 2 · 2023: 5 · 2022: 3 · 2021: 11 · 2020: 8 · 2019: 6 · 2018: 3 · 2017: 3 · 2016: 12 · 2015: 7 · 2014: 6 · 2013: 5 · 2012: 7
FWCI
8.84
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of the Optical Society of America (publishedVersion)
  • PubMed (publishedVersion)
Funders
Johns Hopkins University
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
  • Physical Sciences › Engineering › Biomedical Engineering › Optical Polarization and Ellipsometry
  • Physical Sciences › Engineering › Computational Mechanics › Surface Roughness and Optical Measurements
Keywords
corneal transparency, light scattering, radial distribution function, electron microscopy artifacts, rabbit cornea, light scattering theory
MeSH terms
Animals, Collagen, Cornea, Light, Microscopy, Electron, Models, Biological, Rabbits, Vision, Ocular

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review