The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Comparison of Four Methods of Heterochromatic Photometry
Abstract
Four methods of heterochromatic photometry were employed, using the same four observers in each case. These were (i) two types of direct heterochromatic photometry (direct comparison with white, and step by step), (ii) flicker photometry, and (iii) the minimally distinct-border method (MDB). The MDB method is shown to yield results that are linear and obey Abney’s law. Flicker and MDB methods generate relative luminous-efficiency functions that agree well with each other and also with the CIE standard observer as modified by Judd; the methods of direct heterochromatic photometry yield data that agree fairly well with each other, whereas they differ greatly from the data obtained by flicker or MDB. Luminous efficiency as measured by the direct methods seems to receive a contribution from two sources, (a) achromatic signals of the photopic visual system, which exclusively determine the MDB setting, and (b) chromatic signals of the visual system, which produce extra brightness, the amount of which is related to the saturation of the stimulus used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
XII. Studies in the photometry of lights of different colours
Ives, H. E. (1912) · The London Edinburgh and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786440708637317 · Cited by 124
Chromatic border distinctness and its relation to saturation
Kaiser, P. K., Herzberg, P. A., & Boynton, R. M. (1971) · Vision Research · doi:10.1016/0042-6989(71)90215-x · Cited by 50
Self-citation
Cited by
Spectral sensitivity of the foveal cone photopigments between 400 and 500 nm
Smith, V. C., & Pokorny, J. (1975) · Vision Research · doi:10.1016/0042-6989(75)90203-5 · Cited by 1,318
Stockman, A., & Sharpe, L. T. (2000) · Vision Research · doi:10.1016/s0042-6989(00)00021-3 · Cited by 878
Legge, G. E., Mansfield, J. S., & Chung, S. T. L. (2001) · Vision Research · doi:10.1016/s0042-6989(00)00295-9 · Cited by 642
Visual Sensitivity and Parallel Retinocortical Channels
Shapley, R. (1990) · Annual Review of Psychology · doi:10.1146/annurev.ps.41.020190.003223 · Cited by 321
Lee, B. B., Martin, P. R., & Valberg, A. (1988) · The Journal of Physiology · doi:10.1113/jphysiol.1988.sp017292 · Cited by 291
Metadata
- Authors
- Wagner, G., & Boynton, R. M.
- Venue
- Journal of the Optical Society of America
- Publisher
- Optica Publishing Group
- Published
- 1972-12-01
- Volume
- 62
- Issue
- 12
- Pages
- 1508
- ISSN
- 0030-3941 (ISSN-L)
- OpenAlex
- W2139299519
- Cited by
- 305
- References
- 2
- FWCI
- 2.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Four Methods of Heterochromatic Photometry. https://app.cochat.ai/papers/10.1364/josa.62.001508
- The paper
- Wagner, G., & Boynton, R. M. (1972). Comparison of Four Methods of Heterochromatic Photometry. Journal of the Optical Society of America. https://doi.org/10.1364/josa.62.001508
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.