Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 291

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

The physiological basis of heterochromatic flicker photometry demonstrated in the ganglion cells of the macaque retina.

Open access
Lee, B B, Martin, P R, Valberg, A·1988·The Journal of Physiology

Abstract

1. Heterochromatic flicker photometry is a way of measuring the spectral sensitivity of the human eye. Two lights of different colour are sinusoidally alternated at, typically, 10‐20 Hz, and their relative intensities adjusted by the observer until the sensation of flicker is minimized. This technique has been used to define the human photopic luminosity, or V lambda, function on which photometry is based. 2. We have studied the responses of macaque retinal ganglion cells using this stimulus paradigm. The responses of the phasic ganglion cells go through a minimum at relative radiances very similar to that predicted from the V lambda function. At this point, defined as equal luminance, an abrupt change in response phase was observed. A small residual response at twice the flicker frequency was apparent under some conditions. 3. The spectral sensitivity of parafoveal phasic cells measured in this way corresponded very closely to that of human observers minimizing flicker on the same apparatus. 4. Minima in phasic cell activity were independent of flicker frequency, as is the case in the psychophysical task. 5. The response minima of phasic cells obey the laws of additivity and transitivity which are important characteristics of heterochromatic flicker photometry. 6. As the relative intensities of the lights were altered responses of tonic, spectrally opponent cells usually underwent a gradual phase change with vigorous responses at equal luminance. The responses of tonic cells treated individually or as a population could not be related to the V lambda function in any meaningful way. 7. We conclude that the phasic, magnocellular cell system of the primate visual pathway underlies performance in the psychophysical task of heterochromatic flicker photometry. It is likely that other tasks in which spectral sensitivity conforms to the V lambda function also rely on this cell system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1988.sp017292

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 291

Metadata

Authors
Lee, B. B., Martin, P. R., & Valberg, A.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1988-10
Volume
404
Issue
1
Pages
323-347
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2109019860
Cited by
291
References
25
FWCI
6.31
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The physiological basis of heterochromatic flicker photometry demonstrated in the ganglion cells of the macaque retina. https://app.cochat.ai/papers/10.1113/jphysiol.1988.sp017292
The paper
Lee, B. B., Martin, P. R., & Valberg, A. (1988). The physiological basis of heterochromatic flicker photometry demonstrated in the ganglion cells of the macaque retina. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1988.sp017292

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.