The DOI matches its Crossref record.
Modulation transfer of the human eye as a function of retinal eccentricity
Open accessAbstract
We measured the monochromatic image quality of the eye across a wide visual field (120 degrees), with natural pupil (4 mm) and accommodation (3 diopters). The method is based on the acquisition and the posterior processing of double-pass aerial images of a point source imaged on the retina, which was kept at a fixed distance from the eye at all retinal eccentricities. The two-dimensional modulation transfer functions (MTF's) computed from the aerial images show that astigmatism is the dominant monochromatic aberration in both the fovea and the periphery and is also the major cause of variability among individuals. We found a slower decline in optical quality with eccentricity than had been found by previous measurements. Our foveal results are in close agreement with those of Campbell and Gubisch [J. Physiol. (London) 186, 558-578 (1966)], but off-axis optical quality is much better than found previously by Jennings and Charman [Am. J. Optom. Physiol. Opt. 55, 582-590 (1978); Vision Res. 21, 445-454 (1981)]. The optical system of the eye seems to follow a wide-angle lens design: the optical quality in the center (fovea) is not particularly good (it is far from the diffraction limit at this pupil size), but the modulation transfer function remains roughly constant for a wide visual field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Anatomically accurate, finite model eye for optical modeling
Liou, H.-L., & Brennan, N. A. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.001684 · Cited by 612
Receptive fields of P and M ganglion cells across the primate retina
Croner, L. J., & Kaplan, E. (1995) · Vision Research · doi:10.1016/0042-6989(94)e0066-t · Cited by 492
Towards foveated rendering for gaze-tracked virtual reality
Patney, A., Salvi, M., Kim, J., Kaplanyan, A., Wyman, C., Benty, N., Luebke, D., & Lefohn, A. (2016) · ACM Transactions on Graphics · doi:10.1145/2980179.2980246 · Cited by 491
Peripheral refractive errors in myopic, emmetropic, and hyperopic young subjects
Seidemann, A., Schaeffel, F., Guirao, A., Lopez-Gil, N., & Artal, P. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.002363 · Cited by 266
Self-citationOptical quality of emmetropic and myopic eyes in the periphery measured with high-angular resolution
Jaeken, B., & Artal, P. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8993 · Cited by 75
Self-citation
Metadata
- Authors
- Navarro, R., Williams, D. R., & Artal, P.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1993-02-01
- Volume
- 10
- Issue
- 2
- Pages
- 201
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2089196890
- Cited by
- 218
- References
- 0
- FWCI
- 6.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modulation transfer of the human eye as a function of retinal eccentricity. https://app.cochat.ai/papers/10.1364/josaa.10.000201
- The paper
- Navarro, R., Williams, D. R., & Artal, P. (1993). Modulation transfer of the human eye as a function of retinal eccentricity. Journal of the Optical Society of America A. https://doi.org/10.1364/josaa.10.000201
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.