The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Anatomically accurate, finite model eye for optical modeling
Abstract
There is a need for a schematic eye that models vision accurately under various conditions such as refractive surgical procedures, contact lens and spectacle wear, and near vision. Here we propose a new model eye close to anatomical, biometric, and optical realities. This is a finite model with four aspheric refracting surfaces and a gradient-index lens. It has an equivalent power of 60.35 D and an axial length of 23.95 mm. The new model eye provides spherical aberration values within the limits of empirical results and predicts chromatic aberration for wavelengths between 380 and 750 nm. It provides a model for calculating optical transfer functions and predicting optical performance of the eye.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accommodation-dependent model of the human eye with aspherics
Navarro, R., Santamaría, J., & Bescós, J. (1985) · Journal of the Optical Society of America A · doi:10.1364/josaa.2.001273 · Cited by 438
The chromatic eye: a new reduced-eye model of ocular chromatic aberration in humans
Thibos, L. N., Ye, M., Zhang, X., & Bradley, A. (1992) · Applied Optics · doi:10.1364/ao.31.003594 · Cited by 309
Axial Chromatic Aberration of the Human Eye
Bedford, R. E., & Wyszecki, G. (1957) · Journal of the Optical Society of America · doi:10.1364/josa.47.0564_1 · Cited by 307
The Change in Refractive Power of the Human Eye in Dim and Bright Light
Wald, G., & Griffin, D. R. (1947) · Journal of the Optical Society of America · doi:10.1364/josa.37.000321 · Cited by 244
Modulation transfer of the human eye as a function of retinal eccentricity
Navarro, R., Williams, D. R., & Artal, P. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.000201 · Cited by 218
Applegate, R. A., & Lakshminarayanan, V. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.001611 · Cited by 201
Theoretical Eye Model with Aspherics*
Lotmar, W. (1971) · Journal of the Optical Society of America · doi:10.1364/josa.61.001522 · Cited by 195
Light distribution on the retina of a wide-angle theoretical eye
Kooijman, A. C. (1983) · Journal of the Optical Society of America · doi:10.1364/josa.73.001544 · Cited by 192
Vision, Visual Acuity, and Ocular Refraction of Young Men
Sorsby, A., Sheridan, M., Leary, G. A., & Benjamin, B. (1960) · BMJ · doi:10.1136/bmj.1.5183.1394 · Cited by 186
CORNEAL TOPOGRAPHY: A CLINICAL MODEL
Guillon, M., Lydon, D. P. M., & Wilson, C. (1986) · Ophthalmic and Physiological Optics · doi:10.1016/0275-5408(86)90117-1 · Cited by 177
Cited by
Split-spectrum amplitude-decorrelation angiography with optical coherence tomography
Jia, Y., Tan, O., Tokayer, J., Potsaid, B., Wang, Y., Liu, J. J., Kraus, M. F., Subhash, H., Fujimoto, J. G., Hornegger, J., et al. (2012) · Optics Express · doi:10.1364/oe.20.004710 · Cited by 1,841
The shape of the anterior and posterior surface of the aging human cornea
Dubbelman, M., Sicam, V. A. D. P., & Van der Heijde, G. L. (2006) · Vision Research · doi:10.1016/j.visres.2005.09.021 · Cited by 378
Myopia and peripheral ocular aberrations
Mathur, A., Atchison, D. A., & Charman, W. N. (2009) · Journal of Vision · doi:10.1167/9.10.15 · Cited by 53
Metadata
- Authors
- Liou, H.-L., & Brennan, N. A.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1997-08-01
- Volume
- 14
- Issue
- 8
- Pages
- 1684
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W1989502812
- Cited by
- 612
- References
- 20
- FWCI
- 2.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Anatomically accurate, finite model eye for optical modeling. https://app.cochat.ai/papers/10.1364/josaa.14.001684
- The paper
- Liou, H.-L., & Brennan, N. A. (1997). Anatomically accurate, finite model eye for optical modeling. Journal of the Optical Society of America A. https://doi.org/10.1364/josaa.14.001684
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.