The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Multiframe blind deconvolution of astronomical images
Abstract
Maximum-likelihood estimation techniques are presented for the problem of forming object estimates from turbulence-degraded images when the point-spread functions are unknown. The inability of unconstrained maximum-likelihood methods to form meaningful estimates is acknowledged, and iterative algorithms are derived for estimating the object by using both a penalized maximum-likelihood method and a physically meaningful parameterization of the point-spread functions by phase errors distributed over an aperture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
A practical algorithm for the determination of phase from image and diffraction plane pictures
Gerchberg, R. W. (1972) · Optik · Cited by 4,519
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
On the Convergence Properties of the EM Algorithm
Wu, C. F. J. (1983) · The Annals of Statistics · doi:10.1214/aos/1176346060 · Cited by 3,269
Iterative blind deconvolution method and its applications
Ayers, G. R., & Dainty, J. C. (1988) · Optics Letters · doi:10.1364/ol.13.000547 · Cited by 686
Speckle masking in astronomy: triple correlation theory and applications
Lohmann, A. W., Weigelt, G., & Wirnitzer, B. (1983) · Applied Optics · doi:10.1364/ao.22.004028 · Cited by 580
Blind deconvolution through digital signal processing
Stockham, T. G., Cannon, T. M., & Ingebretsen, R. B. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.9800 · Cited by 341
Blind deconvolution of quantum-limited incoherent imagery: maximum-likelihood approach
Holmes, T. J. (1992) · Journal of the Optical Society of America A · doi:10.1364/josaa.9.001052 · Cited by 205
Automatic multidimensional deconvolution
Lane, R. G., & Bates, R. H. T. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.000180 · Cited by 134
Cited by
Kundur, D., & Hatzinakos, D. (1996) · IEEE Signal Processing Magazine · doi:10.1109/79.489268 · Cited by 1,275
Deconvolution methods for 3-D fluorescence microscopy images
Sarder, P., & Nehorai, A. (2006) · IEEE Signal Processing Magazine · doi:10.1109/msp.2006.1628876 · Cited by 479
Robust Multichannel Blind Deconvolution via Fast Alternating Minimization
Sroubek, F., & Milanfar, P. (2012) · IEEE Transactions on Image Processing · doi:10.1109/tip.2011.2175740 · Cited by 180
Metadata
- Authors
- Schulz, T. J.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1993-05-01
- Volume
- 10
- Issue
- 5
- Pages
- 1064
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W1999747206
- Cited by
- 293
- References
- 9
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiframe blind deconvolution of astronomical images. https://app.cochat.ai/papers/10.1364/josaa.10.001064
- The paper
- Schulz, T. J. (1993). Multiframe blind deconvolution of astronomical images. Journal of the Optical Society of America A. https://doi.org/10.1364/josaa.10.001064
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.