Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 302

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Individual variations in the spatial profile of human macular pigment

Hammond, Billy R., Wooten, Billy R., Snodderly, D. Max·1997·Journal of the Optical Society of America A

Abstract

Individual variations in the spatial profile of macular pigment (MP) density were measured for 32 subjects. Peak density of MP measured with a 460-nm, 12-arcmin stimulus averaged 0.58, standard deviation (SD) = 0.26, with a range of 0.175 to 1.39. To assess the symmetry of the MP distribution, MP density was measured on the horizontal and vertical meridians at +/-1 deg eccentricity. The density varied by no more than 16% at these four locations, indicating a basically symmetric distribution. Based on a linear interpolation between measured locations, the width of the spatial distribution of MP at half the maximal density averaged 1.03 deg, SD = 0.38, with a range of 0.25 to 1.9 deg. The average spatial profile of MP density across subjects was fitted with both an exponential and a Gaussian function. An exponential decay with eccentricity explained more variance in the data than did a Gaussian function. Assuming an exponential decay with eccentricity, once MP density has been measured in the center of the retina (denoted A), MP density at more eccentric locations (X, deg) can be predicted with a standardized equation (MP = A x 10(-0.42x)). For individual cases, small deviations from an exponential function suggest the existence of minor flanking peaks or shoulders for 40% of the subjects. We also examined the temporal stability of the MP profile of four subjects over a time span of 4-14 months and for a single spatial location for ten subjects over a time span of 1-16 years. These longitudinal data show that differences in MP density among subjects are maintained over time, if dietary patterns are stable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/josaa.14.001187

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 302

Metadata

Authors
Hammond, B. R., Wooten, B. R., & Snodderly, D. M.
Venue
Journal of the Optical Society of America A
Published
1997-06-01
Volume
14
Issue
6
Pages
1187
ISSN
  • 1084-7529 (ISSN-L)
  • 1520-8532
OpenAlex
W1985283672
Cited by
302
References
29
FWCI
7.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Individual variations in the spatial profile of human macular pigment. https://app.cochat.ai/papers/10.1364/josaa.14.001187
The paper
Hammond, B. R., Wooten, B. R., & Snodderly, D. M. (1997). Individual variations in the spatial profile of human macular pigment. Journal of the Optical Society of America A. https://doi.org/10.1364/josaa.14.001187

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.