The DOI matches its Crossref record.
Effect of noise correlation on detectability of disk signals in medical imaging
Abstract
Pixel signal-to-noise ratio is one accepted measure of image quality for predicting observer performance in medical imaging. We have found, however, that images with equal pixel signal-to-noise ratio (SNRp) but different correlation properties give quite different observer-performance measures for a simple detection experiment. The SNR at the output of an ideal detector with the ability to prewhiten the noise is also a poor predictor of human performance for disk signals in high-pass noise. We have found constant observer efficiencies for humans relative to the performance of a nonprewhitening detector for this task.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Model observers for assessment of image quality.
Barrett, H. H., Yao, J., Rolland, J. P., & Myers, K. J. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.21.9758 · Cited by 531
Self-citationAbbey, C. K., & Barrett, H. H. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.000473 · Cited by 324
Self-citationSchaefferkoetter, J., Casey, M., Townsend, D., & El Fakhri, G. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/5/1465 · Cited by 85
Metadata
- Authors
- Myers, K. J., Barrett, H. H., Borgstrom, M. C., Patton, D. D., & Seeley, G. W.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1985-10-01
- Volume
- 2
- Issue
- 10
- Pages
- 1752
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2094213283
- Cited by
- 205
- References
- 0
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of noise correlation on detectability of disk signals in medical imaging. https://app.cochat.ai/papers/10.1364/josaa.2.001752
- The paper
- Myers, K. J., Barrett, H. H., Borgstrom, M. C., Patton, D. D., & Seeley, G. W. (1985). Effect of noise correlation on detectability of disk signals in medical imaging. Journal of the Optical Society of America A. https://doi.org/10.1364/josaa.2.001752
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.