On the fundamental imaging-depth limit in two-photon microscopy
Abstract
We have analyzed how the maximal imaging depth of two-photon microscopy in scattering samples depends on properties of the sample and the imaging system. We find that the imaging depth increases with increasing numerical aperture and staining inhomogeneity and with decreasing excitation-pulse duration and scattering anisotropy factor, but is ultimately limited by near-surface fluorescence with slight improvements possible using special detection strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Self-citationNonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
Diffuse radiation in the Galaxy
Henyey, L. C., & Greenstein, J. L. (1941) · The Astrophysical Journal · doi:10.1086/144246 · Cited by 2,913
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Long-term in vivo imaging of experience-dependent synaptic plasticity in adult cortex
Trachtenberg, J. T., Chen, B. E., Knott, G. W., Feng, G., Sanes, J. R., Welker, E., & Svoboda, K. (2002) · Nature · doi:10.1038/nature01273 · Cited by 1,927
Long-term dendritic spine stability in the adult cortex
Grutzendler, J., Kasthuri, N., & Gan, W.-B. (2002) · Nature · doi:10.1038/nature01276 · Cited by 1,198
Determining the optical properties of turbid media by using the adding–doubling method
Prahl, S. A., van Gemert, M. J. C., & Welch, A. J. (1993) · Applied Optics · doi:10.1364/ao.32.000559 · Cited by 931
Kleinfeld, D., Mitra, P. P., Helmchen, F., & Denk, W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.26.15741 · Cited by 832
Self-citationIn vivo dendritic calcium dynamics in neocortical pyramidal neurons
Svoboda, K., Denk, W., Kleinfeld, D., & Tank, D. W. (1997) · Nature · doi:10.1038/385161a0 · Cited by 815
Self-citationYaroslavsky, A. N., Schulze, P. C., Yaroslavsky, I. V., Schober, R., Ulrich, F., & Schwarzmaier, H.-J. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/12/305 · Cited by 651
Theer, P., Hasan, M. T., & Denk, W. (2003) · Optics Letters · doi:10.1364/ol.28.001022 · Cited by 645
Self-citationKogelnik, H. (1965) · Applied Optics · doi:10.1364/ao.4.001562 · Cited by 560
Anatomical and functional imaging of neurons using 2-photon laser scanning microscopy
Denk, W., Delaney, K. R., Gelperin, A., Kleinfeld, D., Strowbridge, B. W., Tank, D. W., & Yuste, R. (1994) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(94)90189-9 · Cited by 348
Self-citationDas Verhalten von Lichtwellen in der Nähe eines Brennpunktes oder einer Brennlinie
Debye, P. (1909) · Annalen der Physik · doi:10.1002/andp.19093351406 · Cited by 186
Conditions for the validity of the Debye integral representation of focused fields
Wolf, E., & Li, Y. (1981) · Optics Communications · doi:10.1016/0030-4018(81)90107-3 · Cited by 169
One-parameter two-term Henyey-Greenstein phase function for light scattering in seawater
Haltrin, V. I. (2002) · Applied Optics · doi:10.1364/ao.41.001022 · Cited by 152
Ultra-deep two-photon fluorescence excitation in turbid media
Beaurepaire, E., Oheim, M., & Mertz, J. C. (2001) · Optics Communications · doi:10.1016/s0030-4018(00)01156-1 · Cited by 138
Development and comparison of models for light-pulse transport through scattering–absorbing media
Mitra, K., & Kumar, S. (1999) · Applied Optics · doi:10.1364/ao.38.000188 · Cited by 138
Stelzer, E. H. K., Hell, S. W., Lindek, S., Stricker, R., Pick, R., Storz, C., Ritter, G., & SALMON, N. J. (1994) · Optics Communications · doi:10.1016/0030-4018(94)90546-0 · Cited by 111
Optical recording of light-evoked calcium signals in the functionally intact retina
Denk, W. T., & Detwiler, P. B. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.12.7035 · Cited by 103
Self-citationTwo-photon excitation in functional biological imaging
Denk, W. T. (1996) · Journal of Biomedical Optics · doi:10.1117/12.242945 · Cited by 90
Self-citationEpifluorescence collection in two-photon microscopy
Beaurepaire, E., & Mertz, J. C. (2002) · Applied Optics · doi:10.1364/ao.41.005376 · Cited by 73
Spatiotemporal model of femtosecond pulse generation in Kerr-lens mode-locked solid-state lasers
Kalosha, V. P., Müller, M., Herrmann, J., & Gatz, S. (1998) · Journal of the Optical Society of America B · doi:10.1364/josab.15.000535 · Cited by 45
Cited by
Scale: a chemical approach for fluorescence imaging and reconstruction of transparent mouse brain
Hama, H., Kurokawa, H., Kawano, H., Ando, R., Shimogori, T., Noda, H., Fukami, K., Sakaue-Sawano, A., & Miyawaki, A. (2011) · Nature Neuroscience · doi:10.1038/nn.2928 · Cited by 1,142
Richardson, D. S., & Lichtman, J. W. (2015) · Cell · doi:10.1016/j.cell.2015.06.067 · Cited by 1,095
Guidestar-assisted wavefront-shaping methods for focusing light into biological tissue
Horstmeyer, R., Ruan, H., & Yang, C. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.140 · Cited by 651
Deep tissue multiphoton microscopy using longer wavelength excitation
Kobat, D., Durst, M. E., Nishimura, N., Wong, A. W., Schaffer, C. B., & Xu, C. (2009) · Optics Express · doi:10.1364/oe.17.013354 · Cited by 574
Advances in multiphoton microscopy technology
Hoover, E. E., & Squier, J. A. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.361 · Cited by 542
Metadata
- Authors
- Theer, P., & Denk, W.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 2006-12-01
- Volume
- 23
- Issue
- 12
- Pages
- 3139
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2141354231
- Cited by
- 399
- References
- 23
- FWCI
- 7.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.