CoChat

Psychophysical estimate of extrafoveal cone spacing

Coletta, Nancy J., Williams, David R. · 1987 · Journal of the Optical Society of America A
Cited by 115

The DOI matches its Crossref record.

Abstract

In the extrafoveal retina, interference fringes at spatial frequencies higher than the resolution limit look like two-dimensional spatial noise, the origin of which has not been firmly established. We show that over a limited range of high spatial frequencies this noise takes on a striated appearance, with the striations running perpendicular to the true fringe orientation. A model of cone aliasing based on anatomical measurements of extrafoveal cone position predicts that this orientation reversal should occur when the period of the interference fringe roughly equals the spacing between cones, i.e., when the fringe spatial frequency is about twice the cone Nyquist frequency. Psychophysical measurements of the orientation reversal at retinal eccentricities from 0.75 to 10 deg are in quantitative agreement with this prediction. This agreement implies that at least part of the spatial noise observed under these conditions results from aliasing by the cone mosaic. The orientation reversal provides a psychophysical method for estimating spacing in less regular mosaics, complementing another psychophysical technique for measuring spacing in the more regular mosaic of foveal cones [D.R. Williams, Vision Res. 25, 195 (1985); Vision Res. (submitted)].

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/josaa.4.001503

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Coletta, N. J., & Williams, D. R.
Venue
Journal of the Optical Society of America A
Published
1987-08-01
Volume
4
Issue
8
Pages
1503
ISSN
  • 1084-7529 (ISSN-L)
  • 1520-8532
OpenAlex
W2165680558
Cited by
115
References
0
FWCI
3.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.