The DOI matches its Crossref record.
Age-related changes in the central visual field for short-wavelength-sensitive pathways
Abstract
The sensitivity of short-wavelength-sensitive (SWS) cone pathways throughout the central 30-deg visual field was determined in both eyes of 62 normal volunteers between the ages of 20 and 72 years. We found an average SWS cone pathway sensitivity decrease with age of approximately 0.15 log unit per decade. The sensitivity reduction was approximately linear, with a slightly larger decrease beyond the age of 50 years. The age-related SWS cone pathway sensitivity reductions also became larger as a function of increasing stimulus eccentricity. Measurements of ocular-media absorption characteristics in each eye revealed that 30-40% of the age-related sensitivity loss could be attributed to reductions in transmission of short-wavelength light by the ocular media. After corrections for preretinal media transmission loss, the decrease in the sensitivity of SWS cone pathways with age was approximately 0.09 log unit per decade. This age-related loss is greater than age-related sensitivity decreases in the middle-wavelength-sensitive and/or long-wavelength-sensitive cones (approximately 0.06 to 0.07 log unit per decade). In the age group older than 60 years, there was an inverse relationship between media-corrected SWS cone pathway sensitivity and media absorption characteristics (i.e., media-corrected SWS cone pathway sensitivity was higher in eyes with lower media transmission of short wavelengths). This relationship was not so evident for younger subjects. A similar inverse relationship between transmission loss in the ocular media and SWS cone pathway sensitivity was found between left and right eyes of the same individual.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Color perception diminishes, especially in the violet-blue-green potion of the spectrum (Johnson, Adams, Twelker, & Quigg, 1988), such that vivid shades of color in the yellow to red portion of the spectrum are more easily discerned.”
From Design Principles to Accommodate Older Adults (2012) · cites this paper as Johnson, Adams, Twelker, & Quigg, 1988
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 40
- Sekuler, 1986, J. Opt. Soc. Am. A, 3, 864, 10.1364/JOSAA.3.000864 · DOI
- Brenton, 1986, Ophthalmologica, 193, 56, 10.1159/000309679 · DOI
- Drance, 1967, Am. J. Ophthalmol., 63, 1667, 10.1016/0002-9394(67)93644-6 · DOI
- Drance, 1967, Can. J. Ophthalmol., 2, 79
- Egge, 1984, Acta Ophthalmol. Suppl., 169, 1
- Haas, 1986, Am. J. Ophthalmol., 101, 199, 10.1016/0002-9394(86)90595-7 · DOI
- Heijl, 1987, Arch. Ophthalmol., 105, 1544, 10.1001/archopht.1987.01060110090039 · DOI
- Jaffe, 1986, Arch. Ophthalmol., 104, 1021, 10.1001/archopht.1986.01050190079043 · DOI
- Johnson, 1987, Appl. Opt., 26, 1449, 10.1364/AO.26.001449 · DOI
- Johnson, 1983, Invest. Ophthalmol. Vis. Sci. Suppl., 24, 132
- Katz, 1987, Arch. Ophthalmol., 105, 1083, 10.1001/archopht.1987.01060080085033 · DOI
- Kilbride, 1986, Vision Res., 26, 321, 10.1016/0042-6989(86)90029-5 · DOI
- van Norren, 1985, Invest. Ophthalmol. Vis. Sci., 26, 1014
- Farber, 1985, Invest. Ophthalmol. Vis. Sci., 26, 1558
- Gartner, 1981, Br. J. Ophthalmol., 65, 23, 10.1136/bjo.65.1.23 · DOI
- Yuodelis, 1986, Vision Res., 26, 847, 10.1016/0042-6989(86)90143-4 · DOI
- Balaszi, 1984, Am. J. Ophthalmol., 97, 760, 10.1016/0002-9394(84)90509-9 · DOI
- Devaney, 1980, J. Gerontol., 35, 836, 10.1093/geronj/35.6.836 · DOI
- Dolman, 1980, Arch. Ophthalmol., 98, 2053, 10.1001/archopht.1980.01020040905024 · DOI
- Scheibel, 1975, Exp. Neurol., 47, 392, 10.1016/0014-4886(75)90072-2 · DOI
- Vrabec, 1965, Br. J. Ophthalmol., 49, 561, 10.1136/bjo.49.11.561 · DOI
- Eisner, 1987, Invest. Ophthalmol. Vis. Sci., 28, 1824
- Schneck, 1988, Invest. Ophthalmol. Vis. Sci. Suppl., 29, 301
- Werner, 1988, J. Opt. Soc. Am. A, 5, 2122, 10.1364/JOSAA.5.002122 · DOI
- van Nooren, 1974, Vision Res., 14, 1237, 10.1016/0042-6989(74)90222-3 · DOI · Paper page
- Mellerio, 1974, Vision Res., 11, 129, 10.1016/0042-6989(71)90229-X · DOI
- Pokorny, 1987, Appl. Opt., 26, 1437, 10.1364/AO.26.001437 · DOI
- Said, 1959, Gerentologica, 3, 213, 10.1159/000210900 · DOI
- Adams, 1982, Am. J. Optom. Physiol. Opt., 59, 954, 10.1097/00006324-198212000-00004 · DOI
- Adams, 1987, Arch. Ophthalmol., 105, 782, 10.1001/archopht.1987.01060060068035 · DOI
- Heron, 1988, Invest. Ophthalmol. Vis. Sci., 29, 64
- Zwas, 1984, Invest. Ophthalmol. Vis. Sci. Suppl., 25, 193
- deMonastario, 1981, Science, 213, 1278, 10.1126/science.7268439 · DOI
- Ahnelt, 1987, J. Comp. Neurol., 255, 18, 10.1002/cne.902550103 · DOI
- Baylor, 1987, J. Physiol., 390, 145, 10.1113/jphysiol.1987.sp016691 · DOI · Paper page
- Ham, 1982, Am. J. Ophthalmol., 93, 299, 10.1016/0002-9394(82)90529-3 · DOI
- Weleber, 1981, Invest. Ophthalmol. Vis. Sci., 20, 392
- Celesia, 1987, Electroenceph. Clin. Neurophys., 68, 161, 10.1016/0168-5597(87)90023-2 · DOI
- Sokol, 1981, Electroenceph. Clin. Neurophys., E51, 559, 10.1016/0013-4694(81)90232-7 · DOI
- Haegerstrom-Portnoy, 1988, J. Opt. Soc. Am. A, 5, 2140, 10.1364/JOSAA.5.002140 · DOI
Cited by
Sorted by citations
Items 101–115 of 115
Statistical modelling of the central 10-degree visual field in short-wavelength automated perimetry
Cubbidge, R., Hosking, S., & Embleton, S. (2002) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-002-0509-4 · Cited by 4
Use of a blue filter in visual field analysis.
Jong, D. L. A., Felius, J., van den Berg, T., & Greve, E. (1992) · British Journal of Ophthalmology · doi:10.1136/bjo.76.7.447-a · Cited by 4
Age-related changes of Glu/GABA expression in the primary visual cortex of cat.
Diao, J., Xu, J.-W., Li, G.-Z., Tang, C.-H., & Hua, T.-M. (2009) · Zoological Research · doi:10.3724/sp.j.1141.2009.01038 · Cited by 3
“…to visual signal (Elliott et al, 1990; ealth Guide for t d 1.2 P f immunohistochemical and Nissl Nomura et al, 2003), decline of sensitivity to wavelength (Johnson et al, 1988; Gray et al, 1995) as well as the selectivity to orientation and/or motion direction of visual stimulus (Willis &…”
BackgroundInfluentialShort-Wavelength Visual Field Testing in Eyes with Primary Open-Angle Glaucoma
Weinreb, R., & Sample, P. (1991) · doi:10.1007/978-3-642-76084-6_22 · Cited by 3
Azuma, K., Inoue, T., Fujino, R., Igarashi, N., Asano, S., Nomura, Y., Hashimoto, Y., Azuma, K., Asaoka, R., Kadonosono, K., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-77025-x · Cited by 2
Beirne, R. (2013) · Vision Research · doi:10.1016/j.visres.2013.04.002 · Cited by 2
“…function has been shown to be significantly reduced in normal older healthy eyes for a variety of stimuli (Beirne et al., 2008; Eisner et al., 1987; Johnson et al., 1988; Werner, Bieber, & Schefrin, 2000; Zlatkova, Coulter, & Anderson, 2003) and functional defects in age-related diseases such as…”
BackgroundJohnson, C. A., Adams, A., & Casson, E. (1992) · Photonics West - Lasers and Applications in Science and Engineering · doi:10.1117/12.137426 · Cited by 2
Self-citationBodis-Wollner, I., & Brannan, J. (1994) · doi:10.3109/01658109409019488 · Cited by 2
Influence of Learning Effect on Blue-On-Yellow Perimetry
Zhong, Y., Chen, L.-L., Cheng, Y., & Huang, P. (2008) · European Journal of Ophthalmology · doi:10.1177/112067210801800313 · Cited by 1
ASSESSING VISUAL FUNCTION IN CLINICAL PRACTICE
Spry, P., & Johnson, C. A. (2000) · doi:10.1016/s0896-1549(05)70200-5 · Cited by 1
Self-citationFactors influencing short wavelength automated perimetry in normal subjects
Herse, P., Coveney, D., & Pham, L. (1998) · doi:10.1111/j.1444-0938.1998.tb06631.x · Cited by 1
Krieglstein, G. (1991) · Springer Berlin Heidelberg · doi:10.1007/978-3-642-76084-6 · Cited by 1
Effects of Different Levels of Intraocular Stray Light on Kinetic Perimetry Findings
Hirasawa, K., Shoji, N., Isono, K., & Tsuchiya, M. (2015) · PLoS ONE · doi:10.1371/journal.pone.0127159
“Many studies have reported a decrease in sensitivity caused by ocular media opacity or induced intraocular stray light measured by standard automated perimetry[12–18], frequency doubling technology [16,17,19–21], or short wave-length automated perimetry[13,17,22,23] within 30° of the visual field.”
MethodCourse and Perception of Ageing in Different Cultures Relevant for Intercultural HCI Design
Heimgärtner, R. (2013) · International Conference on Human Factors in Computing & Informatics · doi:10.1007/978-3-642-39062-3_38
“According to [6], there are three different ways in which ‘functional ageing’ can affect interface development:”
BackgroundSimunovic, M. P. (2011) · Ophthalmology (Rochester, Minn.) · doi:10.1016/j.ophtha.2011.03.022
Metadata
- Authors
- Johnson, C. A., Adams, A. J., Twelker, J. D., & Quigg, J. M.
- Affiliations
- University of California, Davis (US)
- University of California, Berkeley (US)
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1988-12-01
- Volume
- 5
- Issue
- 12
- Pages
- 2131
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2011162836
- Cited by
- 132
- References
- 0
- Citations by year
- 2024: 1 · 2023: 2 · 2021: 1 · 2020: 2 · 2019: 3 · 2018: 2 · 2016: 3 · 2015: 5 · 2014: 4 · 2013: 3 · 2012: 4
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the Optical Society of America A (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Research to Prevent Blindness
- National Eye Institute (EY-03424, EY02271)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Visual perception and processing mechanisms
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
- Keywords
- age-related visual decline, short-wavelength-sensitive cones, S-cones, central visual field, visual sensitivity, stimulus eccentricity, long-wavelength-sensitive cones, interocular comparison
- MeSH terms
- Adult, Aged, Aging, Color Perception, Humans, Middle Aged, Photoreceptor Cells, Visual Fields, Visual Pathways
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review