Comparing measurements of g^(2)(0) performed with different coincidence detection techniques
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
I present measurements of the degree of second-order coherence g(2)(0) for spontaneous parametric downconversion fields and discuss the differences between two-detector (unconditional) and three-detector (conditional) measurements of g(2)(0). An emphasis is placed on comparing measurements made using time-to-amplitude converters (TACs) to those made using a logic circuit, illustrating how the TAC measurements are adversely influenced by dead time effects. Finally, I show how the detrimental effects of dead time when using TACs can be mitigated by renormalizing the measurement results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Coherence and Quantum Optics
Mandel, L., & Wolf, E. (1995) · doi:10.1017/cbo9781139644105 · Cited by 8,356
Correlation between Photons in two Coherent Beams of Light
BROWN, R. H., & TWISS, R. Q. (1956) · Nature · doi:10.1038/177027a0 · Cited by 2,573 · cited 1×
“Indeed, it can be argued that measurements performed by Hanbury Brown and Twiss of quantities related to the degree of second-order coherence are what stimulated the creation of the modern field of quantum optics [1,2].”
BackgroundGrangier, P., Roger, G., & Aspect, A. (1986) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/1/4/004 · Cited by 984
Storage and retrieval of single photons transmitted between remote quantum memories
Chanelière, T., Matsukevich, D. N., Jenkins, S. D., Lan, S.-Y., Kennedy, T. A. B., & Kuzmich, A. (2005) · Nature · doi:10.1038/nature04315 · Cited by 785
Cited by
Zhao, J., Ma, C., Rüsing, M., & Mookherjea, S. (2020) · Physical Review Letters · doi:10.1103/physrevlett.124.163603 · Cited by 362
Integrated spatial multiplexing of heralded single-photon sources
Collins, M. J., Xiong, C., Rey, I. H., Vo, T. D., He, J., Shahnia, S., Reardon, C., Krauss, T. F., Steel, M. J., Clark, A. S., et al. (2013) · Nature Communications · doi:10.1038/ncomms3582 · Cited by 270
Quantum frequency translation of single-photon states in a photonic crystal fiber
McGuinness, H. J., Raymer, M. G., McKinstrie, C. J., & Radic, S. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.093604 · Cited by 254
Measuring photon bunching at ultrashort timescale by two-photon absorption in semiconductors
Boitier, F., Godard, A., Rosencher, E., & Fabre, C. (2009) · Nature Physics · doi:10.1038/nphys1218 · Cited by 195
Ma, C., Wang, X., Anant, V., Beyer, A. D., Shaw, M. D., & Mookherjea, S. (2017) · Optics Express · doi:10.1364/oe.25.032995 · Cited by 137
Metadata
- Authors
- Beck, M.
- Venue
- Journal of the Optical Society of America B
- Publisher
- Optica Publishing Group
- Published
- 2007-11-14
- Volume
- 24
- Issue
- 12
- Pages
- 2972
- ISSN
- 0740-3224 (ISSN-L)
- 1520-8540
- OpenAlex
- W2014881283
- Cited by
- 90
- References
- 4
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparing measurements of g^(2)(0) performed with different coincidence detection techniques. https://app.cochat.ai/papers/10.1364/josab.24.002972
- The paper
- Beck, M. (2007). Comparing measurements of g^(2)(0) performed with different coincidence detection techniques. Journal of the Optical Society of America B. https://doi.org/10.1364/josab.24.002972
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.