The DOI matches its Crossref record.
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
Open accessAbstract
We present theoretical and experimental results which demonstrate the superior sensitivity of swept source (SS) and Fourier domain (FD) optical coherence tomography (OCT) techniques over the conventional time domain (TD) approach. We show that SS- and FD-OCT have equivalent expressions for system signal-to-noise ratio which result in a typical sensitivity advantage of 20-30dB over TD-OCT. Experimental verification is provided using two novel spectral discrimination (SD) OCT systems: a differential fiber-based 800nm FD-OCT system which employs deep-well photodiode arrays, and a differential 1300nm SS-OCT system based on a swept laser with an 87nm tuning range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence Tomography
Leung, C. K.-S., Cheung, C. Y.-L., Weinreb, R. N., Qiu, Q., Liu, S., Li, H., Xu, G., Fan, N., Huang, L., Pang, C.-P., et al. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.04.013 · Cited by 486
Optical coherence tomography (OCT): principle and technical realization
Aumann, S., Donner, S., Fischer, J., & Müller, F. (2019) · High Resolution Imaging in Microscopy and Ophthalmology · doi:10.1007/978-3-030-16638-0_3 · Cited by 449
Comprehensive volumetric optical microscopy in vivo
Yun, S. H., Tearney, G. J., Vakoc, B. J., Shishkov, M., Oh, W. Y., Desjardins, A. E., Suter, M. J., Chan, R. C., Evans, J. A., Jang, I.-K., et al. (2006) · Nature Medicine · doi:10.1038/nm1450 · Cited by 438
Spectral-domain phase microscopy
Choma, M. A., Ellerbee, A. K., Yang, C., Creazzo, T. L., & Izatt, J. A. (2005) · Optics Letters · doi:10.1364/ol.30.001162 · Cited by 342
Self-citationBaumann, B., Baumann, S. O., Konegger, T., Pircher, M., Götzinger, E., Schlanitz, F., Schütze, C., Sattmann, H., Litschauer, M., Schmidt-Erfurth, U., et al. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.001670 · Cited by 163
Metadata
- Authors
- Choma, M., Sarunic, M., Yang, C., & Izatt, J.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2003-09-08
- Volume
- 11
- Issue
- 18
- Pages
- 2183
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2097371977
- Cited by
- 1,794
- References
- 0
- FWCI
- 36.64
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitivity advantage of swept source and Fourier domain optical coherence tomography. https://app.cochat.ai/papers/10.1364/oe.11.002183
- The paper
- Choma, M., Sarunic, M., Yang, C., & Izatt, J. (2003). Sensitivity advantage of swept source and Fourier domain optical coherence tomography. Optics Express. https://doi.org/10.1364/oe.11.002183
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.