The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Characterization of photodamage in coherent anti-Stokes Raman scattering microscopy
Open accessAbstract
We report a mechanistic analysis of photodamage in coherent anti-Stokes Raman scattering (CARS) microscopy. Photodamage to the myelin sheath in spinal tissues is induced by using the point scan mode and is featured by myelin splitting and shockwaves with broadband emission. Our measurement of photodamage rate versus the excitation power reveals that both linear and nonlinear mechanisms are involved. Moreover, we show that vibrational absorption induced by coherent Raman processes significantly contributes to the nonlinear damage at high peak powers. For CARS imaging of cultured cells, the photodamage is characterized by plasma membrane blebbing and is dominated by a second order mechanism. Our study suggests that for dense samples such as the myelin sheath, CARS imaging induced photodamage can be minimized by using laser beams with relatively long near IR wavelengths and a repetition rate of a few MHz. For less dense samples such as cultured cells, laser pulses of higher repetition rates are preferred.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Campagnola, P. J., & Loew, L. M. (2003) · Nature Biotechnology · doi:10.1038/nbt894 · Cited by 1,326
Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy
Evans, C. L., Potma, E. O., Puoris'haag, M., Côté, D., Lin, C. P., & Xie, X. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508282102 · Cited by 957
Highly Nonlinear Photodamage in Two-Photon Fluorescence Microscopy
Hopt, A., & Neher, E. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76173-5 · Cited by 442
Cited by
Label-Free Biomedical Imaging with High Sensitivity by Stimulated Raman Scattering Microscopy
Freudiger, C. W., Min, W., Saar, B. G., Lu, S., Holtom, G. R., He, C., Tsai, J. C., Kang, J. X., & Xie, X. S. (2008) · Science · doi:10.1126/science.1165758 · Cited by 2,255
Coherent Anti-Stokes Raman Scattering Microscopy: Chemical Imaging for Biology and Medicine
Evans, C. L., & Xie, X. S. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112754 · Cited by 1,150
Raman spectroscopy: techniques and applications in the life sciences
Shipp, D. W., Sinjab, F., & Notingher, I. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000315 · Cited by 396
Stimulated Raman scattering microscopy with a robust fibre laser source
Freudiger, C. W., Yang, W., Holtom, G. R., Peyghambarian, N., Xie, X. S., & Kieu, K. Q. (2014) · Nature Photonics · doi:10.1038/nphoton.2013.360 · Cited by 345
Quantum-enhanced nonlinear microscopy
Casacio, C. A., Madsen, L. S., Terrasson, A., Waleed, M., Barnscheidt, K., Hage, B., Taylor, M. A., & Bowen, W. P. (2021) · Nature · doi:10.1038/s41586-021-03528-w · Cited by 344
Metadata
- Authors
- Fu, Y., Wang, H., Shi, R., & Cheng, J.-X.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2006
- Volume
- 14
- Issue
- 9
- Pages
- 3942
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2020170071
- Cited by
- 200
- References
- 3
- FWCI
- 3.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of photodamage in coherent anti-Stokes Raman scattering microscopy. https://app.cochat.ai/papers/10.1364/oe.14.003942
- The paper
- Fu, Y., Wang, H., Shi, R., & Cheng, J.-X. (2006). Characterization of photodamage in coherent anti-Stokes Raman scattering microscopy. Optics Express. https://doi.org/10.1364/oe.14.003942
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.