CoChat

Polar decomposition of 3 x 3 Mueller matrix: a tool for quantitative tissue polarimetry

Open access
Swami, M. K., Manhas, S., Buddhiwant, P., Ghosh, N., Uppal, A., Gupta, P. K. · 2006 · Optics Express
Cited by 101

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The polarization properties of any medium are completely described by the sixteen element Mueller matrix that relates the polarization parameters of the light incident on the medium to that emerging from it. Measurement of all the elements of the matrix requires a minimum of sixteen measurements involving both linear and circularly polarized light. However, for many diagnostic applications, it would be useful if the polarization parameters can be quantified with linear polarization measurements alone. In this paper, we present a method based on polar decomposition of Mueller matrix for quantification of the polarization parameters of a scattering medium using the nine element (3 x 3) Mueller matrix that requires linear polarization measurements only. The methodology for decomposition of the 3 x 3 Mueller matrix is based on the previously developed decomposition process for sixteen element (4 x 4) Mueller matrix but with an assumption that the depolarization of linearly polarized light due to scattering is independent of the orientation angle of the incident linear polarization vector. Studies conducted on various scattering samples demonstrated that this assumption is valid for a turbid medium like biological tissue where the depolarization of linearly polarized light primarily arises due to the randomization of the field vector's direction as a result of multiple scattering. For such medium, polar decomposition of 3 x 3 Mueller matrix can be used to quantify the four independent polarization parameters namely, the linear retardance (delta ), the circular retardance (psi), the linear depolarization coefficient (Delta) and the linear diattenuation (d) with reasonable accuracy. Since this approach requires measurements using linear polarizers only, it considerably simplifies measurement procedure and might find useful applications in tissue diagnosis using the retrieved polarization parameters.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/oe.14.009324

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 101

Metadata

Authors
Swami, M. K., Manhas, S., Buddhiwant, P., Ghosh, N., Uppal, A., & Gupta, P. K.
Venue
Optics Express
Published
2006
Volume
14
Issue
20
Pages
9324
ISSN
1094-4087 (ISSN-L)
OpenAlex
W2069799035
Cited by
101
References
2
FWCI
2.44
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Polar decomposition of 3 x 3 Mueller matrix: a tool for quantitative tissue polarimetry. https://app.cochat.ai/papers/10.1364/oe.14.009324
The paper
Swami, M. K., Manhas, S., Buddhiwant, P., Ghosh, N., Uppal, A., & Gupta, P. K. (2006). Polar decomposition of 3 x 3 Mueller matrix: a tool for quantitative tissue polarimetry. Optics Express. https://doi.org/10.1364/oe.14.009324

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.