The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Optical microfiber coil resonator refractometric sensor
Open accessAbstract
We present a novel refractometric sensor based on a coated all-coupling optical-fiber-nanowire microcoil resonator which is robust, compact, and comprises an intrinsic fluidic channel. We calculate the device sensitivity and find its dependence on the nanowire diameter and coating thickness. A sensitivity as high as 700 nm/RIU and a refractive index resolution as low as 10(-10) are predicted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultra-high-Q toroid microcavity on a chip
Armani, D. K., Kippenberg, T. J., Spillane, S. M., & Vahala, K. J. (2003) · Nature · doi:10.1038/nature01371 · Cited by 2,214
Cited by
Sensitive optical biosensors for unlabeled targets: A review
Fan, X., White, I. M., Shopova, S. I., Zhu, H., Suter, J. D., & Sun, Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.05.022 · Cited by 2,187
Vollmer, F., & Yang, L. (2012) · nanoph · doi:10.1515/nanoph-2012-0021 · Cited by 546
Optical fibre nanowires and microwires: a review
Brambilla, G. (2010) · Journal of Optics · doi:10.1088/2040-8978/12/4/043001 · Cited by 370
Self-citationJiang, X., Qavi, A. J., Huang, S. H., & Yang, L. (2020) · Matter · doi:10.1016/j.matt.2020.07.008 · Cited by 353
Metadata
- Authors
- Xu, F., Horak, P., & Brambilla, G.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2007
- Volume
- 15
- Issue
- 12
- Pages
- 7888
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2094825647
- Cited by
- 217
- References
- 1
- FWCI
- 18.59
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.