Multifocal multiphoton excitation and time correlated single photon counting detection for 3-D fluorescence lifetime imaging
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We report a multifocal multiphoton time-correlated single photon counting (TCSPC) fluorescence lifetime imaging (FLIM) microscope system that uses a 16 channel multi-anode PMT detector. Multiphoton excitation minimizes out-of-focus photobleaching, multifocal excitation reduces non-linear in-plane photobleaching effects and TCSPC electronics provide photon-efficient detection of the fluorescence decay profile. TCSPC detection is less prone to bleaching- and movement-induced artefacts compared to wide-field time-gated or frequency-domain FLIM. This microscope is therefore capable of acquiring 3-D FLIM images at significantly increased speeds compared to single beam multiphoton microscopy and we demonstrate this with live cells expressing a GFP tagged protein. We also apply this system to time-lapse FLIM of NAD(P)H autofluorescence in single live cells and report measurements on the change in the fluorescence decay profile following the application of a known metabolic inhibitor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265
Highly Nonlinear Photodamage in Two-Photon Fluorescence Microscopy
Hopt, A., & Neher, E. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76173-5 · Cited by 442
Cited by
Fluorescence lifetime imaging – techniques and applications
BECKER, W. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03618.x · Cited by 890
Datta, R., Heaster, T. M., Sharick, J. T., Gillette, A. A., & Skala, M. C. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.7.071203 · Cited by 880
Fluorescence lifetime imaging (FLIM): Basic concepts and some recent developments
Suhling, K., Hirvonen, L. M., Levitt, J. A., Chung, P.-H., Tregidgo, C., Le Marois, A., Rusakov, D. A., Zheng, K., Ameer-Beg, S., Poland, S., et al. (2015) · Medical Photonics · doi:10.1016/j.medpho.2014.12.001 · Cited by 313
Fluorescence Lifetime Techniques in Medical Applications
Marcu, L. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0495-y · Cited by 257
Fluorescence lifetime and polarization-resolved imaging in cell biology
Levitt, J. A., Matthews, D. R., Ameer-Beg, S. M., & Suhling, K. (2009) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2009.01.004 · Cited by 205
“Recent technical advances have allowed for more rapid acquisition in multiphoton FLIM by the use of multiple scanning beams [13,19,20] and spinning (Nipkow) discs [21,22].”
MethodFluorescence lifetime imaging microscopy in life sciences
Borst, J. W., & Visser, A. J. W. G. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/10/102002 · Cited by 168
Evolution and impact of high content imaging.
Way, G. P., Sailem, H., Shave, S., Kasprowicz, R., & Carragher, N. O. (2023) · SLAS Discovery · doi:10.1016/j.slasd.2023.08.009 · Cited by 67
Metadata
- Authors
- Kumar, S., Dunsby, C., Beule, P. A. A. D., Owen, D. M., Anand, U., Lanigan, P. M. P., Benninger, R. K. P., Davis, D. M., Neil, M. A. A., Anand, P., Benham, C., Naylor, A., & French, P. M. W.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2007-09-17
- Volume
- 15
- Issue
- 20
- Pages
- 12548
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2154329137
- Cited by
- 77
- References
- 2
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.