High efficiency NbN nanowire superconducting single photon detectors fabricated on MgO substrates from a low temperature process
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We demonstrate high-performance nanowire superconducting single photon detectors (SSPDs) on bN thin films grown at a temperature compatible with monolithic integration. NbN films ranging from 150 nm to 3 nm in thickness were deposited by dc magnetron sputtering on MgO substrates at 400 degrees C SSPDs were fabricated on high quality NbN films of different thickness (7 to 3 nm) deposited under optimal conditions. Electrical and optical characterizations were performed on the SSPDs. The highest QE value measured at 4.2K is 20% at 1300 nm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Picosecond superconducting single-photon optical detector
Gol’tsman, G. N., Okunev, O., Chulkova, G., Lipatov, A., Semenov, A., Smirnov, K., Voronov, B., Dzardanov, A., Williams, C., & Sobolewski, R. (2001) · Applied Physics Letters · doi:10.1063/1.1388868 · Cited by 1,597
Demonstration of a low-noise near-infrared photon counter with multiphoton discrimination
Miller, A. J., Nam, S. W., Martinis, J. M., & Sergienko, A. V. (2003) · Applied Physics Letters · doi:10.1063/1.1596723 · Cited by 285
Cited by
Multiphoton entanglement and interferometry
Pan, J.-W., Chen, Z.-B., Lu, C.-Y., Weinfurter, H., Zeilinger, A., & Żukowski, M. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.777 · Cited by 1,410
Waveguide-integrated superconducting nanowire single-photon detectors
Ferrari, S., Schuck, C., & Pernice, W. (2017) · Nanophotonics · doi:10.1515/nanoph-2018-0059 · Cited by 167
Waveguide photon-number-resolving detectors for quantum photonic integrated circuits
Sahin, D., Gaggero, A., Zhou, Z., Jahanmirinejad, S., Mattioli, F., Leoni, R., Beetz, J., Lermer, M., Kamp, M., Höfling, S., et al. (2013) · Applied Physics Letters · doi:10.1063/1.4820842 · Cited by 79
Self-citationQuantum optical coherence tomography of a biological sample
Nasr, M. B., Goode, D. P., Nguyen, N., Rong, G., Yang, L., Reinhard, B. M., Saleh, B. E. A., & Teich, M. C. (2009) · Optics Communications · doi:10.1016/j.optcom.2008.11.061 · Cited by 79
Photon-number-resolving superconducting nanowire detectors
Mattioli, F., Zhou, Z., Gaggero, A., Gaudio, R., Jahanmirinejad, S., Sahin, D., Marsili, F., Leoni, R., & Fiore, A. (2015) · Superconductor Science and Technology · doi:10.1088/0953-2048/28/10/104001 · Cited by 61
Self-citationA superconducting nanowire single photon detector on lithium niobate
Tanner, M. G., Alvarez, L. S. E., Jiang, W., Warburton, R. J., Barber, Z. H., & Hadfield, R. H. (2012) · Nanotechnology · doi:10.1088/0957-4484/23/50/505201 · Cited by 51
Metadata
- Authors
- Marsili, F., Bitauld, D., Fiore, A., Gaggero, A., Mattioli, F., Leoni, R., Benkahoul, M., & Lévy, F.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2008
- Volume
- 16
- Issue
- 5
- Pages
- 3191
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W1997051023
- Cited by
- 64
- References
- 2
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- doi.org/10.1364/OA_License_v1#VOR-OA (vor, 52 d)
- opg.optica.org/policies/opg-tdm-policy.json (tdm, 52 d)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.