The DOI matches its Crossref record.
Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range
Open accessAbstract
We present an application of in vivo anterior segment imaging of the human eye with an ultrahigh speed swept source OCT instrument. For this purpose, a dedicated OCT system was designed and constructed. This instrument enables axial zooming by automatic reconfiguration of spectral sweep range; an enhanced imaging range mode enables imaging of the entire anterior segment while a high axial resolution mode provides detailed morphological information of the chamber angle and the cornea. The speed of 200,000 lines/s enables high sampling density in three-dimensional imaging of the entire cornea in 250 ms promising future applications of OCT for optical corneal topography, pachymetry and elevation maps. The results of a preliminary quantitative corneal analysis based on OCT data free form motion artifacts are presented. Additionally, a volumetric and real time reconstruction of dynamic processes, like pupillary reaction to light stimulus or blink-induced contact lens movements are demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Grulkowski, I., Liu, J. J., Potsaid, B., Jayaraman, V., Lu, C. D., Jiang, J., Cable, A. E., Duker, J. S., & Fujimoto, J. G. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002733 · Cited by 308
In vivo structural imaging of the cornea by polarization-resolved second harmonic microscopy
Latour, G., Gusachenko, I., Kowalczuk, L., Lamarre, I., & Schanne-Klein, M.-C. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000001 · Cited by 139
Metadata
- Authors
- Gora, M., Karnowski, K., Szkulmowski, M., Kaluzny, B. J., Huber, R., Kowalczyk, A., & Wojtkowski, M.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2009-08-06
- Volume
- 17
- Issue
- 17
- Pages
- 14880
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W1978395256
- Cited by
- 217
- References
- 0
- FWCI
- 14.56
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range. https://app.cochat.ai/papers/10.1364/oe.17.014880
- The paper
- Gora, M., Karnowski, K., Szkulmowski, M., Kaluzny, B. J., Huber, R., Kowalczyk, A., & Wojtkowski, M. (2009). Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range. Optics Express. https://doi.org/10.1364/oe.17.014880
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.