The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Quantitative cerebral blood flow with Optical Coherence Tomography
Open accessAbstract
Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal monitoring of CBF with high resolution in rats and mice. Using three-dimensional Doppler Optical Coherence Tomography and cranial window preparations, we present methods and algorithms for regional CBF measurements in the rat cortex. Towards this end, we develop and validate a quantitative statistical model to describe the effect of static tissue on velocity sensitivity. This model is used to design scanning protocols and algorithms for sensitive 3D flow measurements and angiography of the cortex. We also introduce a method of absolute flow calculation that does not require explicit knowledge of vessel angles. We show that OCT estimates of absolute CBF values in rats agree with prior measures by autoradiography, suggesting that Doppler OCT can perform absolute flow measurements in animal models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kleinfeld, D., Mitra, P. P., Helmchen, F., & Denk, W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.26.15741 · Cited by 832
Penetrating arterioles are a bottleneck in the perfusion of neocortex
Nishimura, N., Schaffer, C. B., Friedman, B., Lyden, P. D., & Kleinfeld, D. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609551104 · Cited by 367
Cited by
Jia, Y., Bailey, S. T., Wilson, D. J., Tan, O., Klein, M. L., Flaxel, C. J., Potsaid, B., Liu, J. J., Lu, C. D., Kraus, M. F., et al. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.01.034 · Cited by 729
Self-citationLi, L., Zhu, L., Ma, C., Lin, L., Yao, J., Wang, L., Maslov, K., Zhang, R., Chen, W., Shi, J., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0071 · Cited by 477
Optical coherence tomography based angiography [Invited]
Chen, C.-L., & Wang, R. K. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001056 · Cited by 415
Metadata
- Authors
- Srinivasan, V. J., Sakadžić, S., Gorczynska, I., Ruvinskaya, S., Wu, W., Fujimoto, J. G., & Boas, D. A.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2010-01-22
- Volume
- 18
- Issue
- 3
- Pages
- 2477
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2022606330
- Cited by
- 248
- References
- 2
- FWCI
- 11.29
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative cerebral blood flow with Optical Coherence Tomography. https://app.cochat.ai/papers/10.1364/oe.18.002477
- The paper
- Srinivasan, V. J., Sakadžić, S., Gorczynska, I., Ruvinskaya, S., Wu, W., Fujimoto, J. G., & Boas, D. A. (2010). Quantitative cerebral blood flow with Optical Coherence Tomography. Optics Express. https://doi.org/10.1364/oe.18.002477
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.