The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly sensitive graphene biosensors based on surface plasmon resonance
Open accessAbstract
A surface plasmon resonance (SPR) based graphene biosensor is presented. It consists of a graphene sheet coated above a gold thin film, which has been proposed and experimentally fabricated recently [ChemPhysChem 11, 585 (2010)]. The biosensor uses attenuated total reflection (ATR) method to detect the refractive index change near the sensor surface, which is due to the adsorption of biomolecules. Our calculations show that the proposed graphene-on-gold SPR biosensor (with L graphene layers) is (1 + 0.025 L) x gamma (where gamma > 1) times more sensitive than the conventional gold thin film SPR biosensor. The improved sensitivity is due to increased adsorption of biomolecules on graphene (represented by the factor gamma) and the optical property of graphene.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fine Structure Constant Defines Visual Transparency of Graphene
Nair, R. R., Blake, P., Grigorenko, A. N., Novoselov, K. S., Booth, T. J., Stauber, T., Peres, N. M. R., & Geim, A. K. (2008) · Science · doi:10.1126/science.1156965 · Cited by 9,084
Cited by
Science and technology roadmap for graphene, related two-dimensional crystals, and hybrid systems
Ferrari, A. C., Bonaccorso, F., Fal'ko, V., Novoselov, K. S., Roche, S., Bøggild, P., Borini, S., Koppens, F. H. L., Palermo, V., Pugno, N., et al. (2015) · Nanoscale · doi:10.1039/c4nr01600a · Cited by 3,027
Biological and chemical sensors based on graphene materials
Liu, Y., Dong, X., & Chen, P. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15270j · Cited by 1,748
Nanochemistry and Nanomedicine for Nanoparticle-based Diagnostics and Therapy
Chen, G., Roy, I., Yang, C., & Prasad, P. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00148 · Cited by 1,499
Surface Plasmon Resonance: A Versatile Technique for Biosensor Applications
Nguyen, H., Park, J., Kang, S., & Kim, M. (2015) · Sensors · doi:10.3390/s150510481 · Cited by 1,357
Nanomaterials enhanced surface plasmon resonance for biological and chemical sensing applications
Zeng, S., Baillargeat, D., Ho, H.-P., & Yong, K.-T. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60479a · Cited by 1,230
Metadata
- Authors
- Wu, L., Chu, H. S., Koh, W. S., & Li, E. P.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2010-06-21
- Volume
- 18
- Issue
- 14
- Pages
- 14395
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W1994788959
- Cited by
- 969
- References
- 1
- FWCI
- 13.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly sensitive graphene biosensors based on surface plasmon resonance. https://app.cochat.ai/papers/10.1364/oe.18.014395
- The paper
- Wu, L., Chu, H. S., Koh, W. S., & Li, E. P. (2010). Highly sensitive graphene biosensors based on surface plasmon resonance. Optics Express. https://doi.org/10.1364/oe.18.014395
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.