The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Accuracy of the Gaussian Point Spread Function model in 2D localization microscopy
Open accessAbstract
The gaussian function is simple and easy to implement as Point Spread Function (PSF) model for fitting the position of fluorescent emitters in localization microscopy. Despite its attractiveness the appropriateness of the gaussian is questionable as it is not based on the laws of optics. Here we study the effect of emission dipole orientation in conjunction with optical aberrations on the localization accuracy of position estimators based on a gaussian model PSF. Simulated image spots, calculated with all effects of high numerical aperture, interfaces between media, polarization, dipole orientation and aberrations taken into account, were fitted with a gaussian PSF based Maximum Likelihood Estimator. For freely rotating dipole emitters it is found that the gaussian works fine. The same, theoretically optimum, localization accuracy is found as if the true PSF were a gaussian, even for aberrations within the usual tolerance limit of high-end optical imaging systems such as microscopes (Marechal's diffraction limit). For emitters with a fixed dipole orientation this is not the case. Localization errors are found that reach up to 40 nm for typical system parameters and aberration levels at the diffraction limit. These are systematic errors that are independent of the total photon count in the image. The gaussian function is therefore inappropriate, and more sophisticated PSF models are a practical necessity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Cited by
A review of progress in single particle tracking: from methods to biophysical insights
Manzo, C., & Garcia-Parajo, M. F. (2015) · Reports on Progress in Physics · doi:10.1088/0034-4885/78/12/124601 · Cited by 597
Single Particle Tracking: From Theory to Biophysical Applications
Shen, H., Tauzin, L. J., Baiyasi, R., Wang, W., Moringo, N., Shuang, B., & Landes, C. F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00815 · Cited by 536
Precisely and accurately localizing single emitters in fluorescence microscopy
Deschout, H., Zanacchi, F. C., Mlodzianoski, M., Diaspro, A., Bewersdorf, J., Hess, S. T., & Braeckmans, K. (2014) · Nature Methods · doi:10.1038/nmeth.2843 · Cited by 498
DAOSTORM: an algorithm for high- density super-resolution microscopy
Holden, S. J., Uphoff, S., & Kapanidis, A. N. (2011) · Nature Methods · doi:10.1038/nmeth0411-279 · Cited by 440
rapidSTORM: accurate, fast open-source software for localization microscopy
Wolter, S., Löschberger, A., Holm, T., Aufmkolk, S., Dabauvalle, M.-C., van de Linde, S., & Sauer, M. (2012) · Nature Methods · doi:10.1038/nmeth.2224 · Cited by 379
Metadata
- Authors
- Stallinga, S., & Rieger, B.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2010-11-09
- Volume
- 18
- Issue
- 24
- Pages
- 24461
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2057543913
- Cited by
- 234
- References
- 2
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.