The DOI matches its Crossref record.
High-speed terahertz time-domain spectroscopy of cyclotron resonance in pulsed magnetic field
Open accessAbstract
We present time-resolved cyclotron resonance spectra of holes in p-Ge measured during single magnetic field pulses by using a rapid-scanning, fiber-coupled terahertz time-domain spectroscopy system. The key component of the system is a rotating monolithic delay line featuring four helicoid mirror surfaces. It allows measurements of THz spectra at up to 250 Hz repetition rate. Here we show results taken at 150 Hz. In a single 900 ms measurement 135 cyclotron resonance spectra were recorded that fully agree with what is expected from literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Conventional terahertz TDS systems with delay lengths of several 100 picoseconds achieve measurement speeds of only a few to a few hundred pulse traces per second, falling short of high-speed monitoring requirements.
“For a delay length of several 100 picoseconds, the measurement speed of conventional systems ranges from a few to few 100 terahertz pulse traces per second [15][16][17], and thus falls short of the requirements for high-speed monitoring.”
From Fastest Thickness Measurements with a Terahertz Time-Domain System Based on Electronically Controlled Optical Sampling (2019) · cites this paper as [17]
The Introduction says earlier THz TDS systems were limited by slow mechanical delay scanning and long acquisition times in pulsed magnetic fields. It does not give the claimed range of trace rates for conventional systems or tie that range to delays of several hundred picoseconds. The 140 ps delay and rates up to 250 Hz in the High-speed delay line section describe this paper’s new system, not conventional systems. (LLM, conf=0.85)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 8
- Dresselhaus, 1955, Phys. Rev., 98, 368, 10.1103/PhysRev.98.368 · DOI
- Suzuki, 1974, Phys. Rev. B, 9, 4184, 10.1103/PhysRevB.9.4184 · DOI
- Larrabee, 2004, Opt. Lett., 29, 122, 10.1364/OL.29.000122 · DOI
- Some, 1994, Appl. Phys. Lett., 65, 3377, 10.1063/1.112397 · DOI
- Wang, 2007, Opt. Lett., 32, 2845
- Wang, 2010, Opt. Express, 18, 12354, 10.1364/OE.18.012354 · DOI
- Crooker, 2002, Rev. Sci. Instrum., 73, 3258, 10.1063/1.1498904 · DOI
- Wang, 2009, Appl. Opt., 48, 1998, 10.1364/AO.48.001998 · DOI
Cited by
Sorted by citations
Baxter, J. B., & Guglietta, G. W. (2011) · Analytical Chemistry · doi:10.1021/ac200907z · Cited by 477
Terahertz-time domain spectrometer with 90 dB peak dynamic range
Vieweg, N., Rettich, F., Deninger, A., Roehle, H., Dietz, R., Göbel, T., & Schell, M. (2014) · Journal of Infrared Millimeter and Terahertz Waves · doi:10.1007/s10762-014-0085-9 · Cited by 203
Yahyapour, M., Jahn, A., Dutzi, K., Puppe, T., Leisching, P., Schmauss, B., Vieweg, N., & Deninger, A. (2019) · Applied Sciences · doi:10.3390/app9071283 · Cited by 63
Interferometry-aided terahertz time-domain spectroscopy
Molter, D., Trierweiler, M., Ellrich, F., Jonuscheit, J., & Von Freymann, G. (2017) · Optics Express · doi:10.1364/oe.25.007547 · Cited by 37
Self-citationTime-domain terahertz spectroscopy in high magnetic fields
Baydin, A., Makihara, T., Peraca, N. M., & Kono, J. (2021) · Frontiers of Optoelectronics · doi:10.1007/s12200-020-1101-4 · Cited by 34
Metadata
- Authors
- Molter, D., Ellrich, F., Weinland, T., George, S., Goiran, M., Keilmann, F., Beigang, R., & Léotin, J.
- Affiliations
- Fraunhofer Institute for Physical Measurement Techniques (DE)
- Centre National de la Recherche Scientifique (FR)
- Max Planck Society (DE)
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2010-11-30
- Volume
- 18
- Issue
- 25
- Pages
- 26163
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W1987300370
- Cited by
- 44
- References
- 0
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 3 · 2022: 3 · 2021: 1 · 2020: 2 · 2019: 3 · 2018: 1 · 2017: 2 · 2016: 7 · 2014: 6 · 2013: 5 · 2012: 4
- FWCI
- 3.53
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Optics Express (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion)
- Max Planck Institute for Plasma Physics (submittedVersion)
- Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion, other-oa)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Funders
- Deutsche Forschungsgemeinschaft
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
- Keywords
- cyclotron resonance, terahertz time-domain spectroscopy, p-type germanium, holes, pulsed magnetic field, high-speed measurement, time-resolved spectra
- MeSH terms
- Electromagnetic Fields, Equipment Design, Computer-Aided Design, Cyclotrons, Equipment Failure Analysis, Terahertz Spectroscopy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review