Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index; 4 of the 22 sources its claims cite were checked for support.

Terahertz-time domain spectrometer with 90 dB peak dynamic range

Open access
Vieweg, N., Rettich, F., Deninger, A., Roehle, H., Dietz, R., Göbel, T., Schell, M. · 2014 · Journal of Infrared Millimeter and Terahertz Waves

Abstract

A single pulse trace of 50 ps is acquired in only 44 ms, and transformed into a spectrum with a peak dynamic range of 60 dB. With 1000 averages, the dynamic range increases to 90 dB.

Overview

CoChat Summary

TL;DR

The paper presents a compact, fiber-coupled terahertz time-domain spectrometer operating at 1.5 μm with InGaAs/InAlAs photoconductive switches, achieving a 90 dB peak dynamic range with 1000 averages in under one minute. It demonstrates the system for terahertz spectroscopy of polymers and terahertz imaging.

Key findings

  • A single 50 ps pulse trace is acquired in 44 ms with a peak dynamic range (PDR) of 60 dB; 100 averages give 82 dB in 4.4 s, and 1000 averages give 90 dB while remaining well below one minute.
  • The system has a bandwidth exceeding 4.5 THz with a signal peak at approximately 480 GHz, a terahertz pulse width of 650 fs, and a timing jitter of approximately 1.3 fs; the precise delay stage is said to improve PDR by more than 17 dB.
  • Spectroscopy of HDPE (1.93 mm), PA (1.07 mm), and LCP (2.05 mm) shows HDPE absorption <0.1 cm⁻¹ below 1 THz and ~1 cm⁻¹ at 2 THz with refractive index 1.53; PA has refractive index 1.71 at 0.5 THz; LCP shows ordinary/extraordinary refractive indices of 1.86 and 2.03 at 0.5 THz and an absorption peak near 1.2 THz attributed to Talcum.
  • Imaging examples reveal a speaker and circuit board inside a mail envelope and air bubbles in a polyamide step wedge; the 90 dB PDR is described as a record for commercial TD-THz systems.

Methods

  • Design and characterization of a compact fiber-coupled THz-TDS system using a 1560 nm femtosecond fiber laser, a fast voice-coil delay stage, a long-travel delay line, and InGaAs/InAlAs photoconductive emitter and detector antennas.
  • Spectroscopy used three polymer samples in a dry-air-purged box, with 1000 averages per trace (44 s measurement time) and material parameters extracted via a quasi-space algorithm comparing reference and sample pulses.
  • Imaging used two test samples mounted on an XY scanner: a mail envelope with a birthday card and a polyamide step wedge, with specified scan areas, step sizes, speeds, and total measurement times.

Limitations

  • The paper states that strong terahertz absorption in LCP and PA at high frequencies lowers the dynamic range and restricts the frequency span usable for analysis to ~2 THz.
  • The paper notes that absolute PDR depends on other factors such as available terahertz power, receiver sensitivity, and electronic noise in the readout circuit.
  • No dedicated limitations section is included; evident from the text, the imaging demonstrations were proof-of-principle and slow, with total measurement times just below two hours for the envelope and 65 min for the step wedge.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1007/s10762-014-0085-9

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

2 Valid · 1 Not valid · 6 Not checked · 39 Own results and interpretations

20 more claims

Create a free account to see all 48 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 6
  • It may state two separate claims as one. 21

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

3 of 3

Citations

Cites

Show all 43 references

Research works printed but not linked: 2

  1. C. H. Zhang, G. F. Zhao, B. B. Jin, Y. Y. Hou, H. H. Jia, J. Chen, and P. H. Wu, “Terahertz imaging on subcutaneous tissues and liver inflamed by liver cancer cells,” Terahertz Sci. Technol., vol. 5, no. 3, pp. 114–123, 2012.
  2. L. Wu, “Optimierung des Signal-Rausch-Abstands von AD-Wandlern,” Elektron. Ind., vol. 11, pp. 50–52, 2010.

Cited by

See all 203

Metadata

Authors
Vieweg, N., Rettich, F., Deninger, A., Roehle, H., Dietz, R., Göbel, T., & Schell, M.
Affiliations
  • Toptica Photonics (Germany) (DE)
  • Fraunhofer Institute for Telecommunications, Heinrich Hertz Institute (DE)
Corresponding author
Vieweg, N.
Venue
Journal of Infrared Millimeter and Terahertz Waves
Published
2014-07-09
Volume
35
Issue
10
Pages
823-832
ISSN
  • 1866-6892 (ISSN-L)
  • 1866-6906
OpenAlex
W1997920385
Cited by
203
References
43
Citations by year
2026: 9 · 2025: 12 · 2024: 18 · 2023: 14 · 2022: 13 · 2021: 16 · 2020: 26 · 2019: 26 · 2018: 18 · 2017: 17 · 2016: 16 · 2015: 15 · 2014: 3
FWCI
9.03
Type
journal article
Language
en
Open access
Locations
  • Journal of Infrared Millimeter and Terahertz Waves (publishedVersion, cc-by)
  • Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
Keywords
dynamic range, time-domain reconstruction, signal averaging, terahertz imaging, terahertz spectroscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Terahertz-time domain spectrometer with 90 dB peak dynamic range. https://app.cochat.ai/papers/10.1007/s10762-014-0085-9
The paper
Vieweg, N., Rettich, F., Deninger, A., Roehle, H., Dietz, R., Göbel, T., & Schell, M. (2014). Terahertz-time domain spectrometer with 90 dB peak dynamic range. Journal of Infrared Millimeter and Terahertz Waves. https://doi.org/10.1007/s10762-014-0085-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.