Spherical reference cavities for frequency stabilization of lasers in non-laboratory environments
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We present an optical cavity design that is insensitive to both vibrations and orientation. The design is based on a spherical cavity spacer that is held rigidly at two points on a diameter of the sphere. Coupling of the support forces to the cavity length is reduced by holding the sphere at a "squeeze insensitive angle" with respect to the optical axis. Finite element analysis is used to calculate the acceleration sensitivity of the spherical cavity for the ideal geometry as well as for several varieties of fabrication errors. The measured acceleration sensitivity for an initial, sub-ideal version of the mounted cavity is 4.0(5)×10(-11)/g, 1.6(3)×10(-10)/g, and 3.1(1)×10(-10)/g (where g = 9.81 m/s2) for accelerations along the vertical and two horizontal directions, and the fractional frequency stability of a laser locked to the cavity is 1.2×10(-15) between 0.4 and 13 s. This low acceleration sensitivity combined with the orientation insensitivity that comes with a rigid mount indicates that this cavity design could allow frequency stable lasers to operate in non-laboratory environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Self-citationFrequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Self-citationMa, L.-S., Jungner, P., Ye, J., & Hall, J. L. (1994) · Optics Letters · doi:10.1364/ol.19.001777 · Cited by 566
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Generation of ultrastable microwaves via optical frequency division
Fortier, T. M., Kirchner, M. S., Quinlan, F., Taylor, J., Bergquist, J. C., Rosenband, T., Lemke, N., Ludlow, A., Jiang, Y., Oates, C. W., et al. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.121 · Cited by 887
Self-citationMehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“…frequency instabilities of the laser, the cavity commonly lies on its support and is not rigidly clamped (Chen et For reasons of compactness and reduction of inertial forces, often cavities of only about 5 cm length have been chosen (Leibrandt et al 2011b, Webster et al 2011, Parker et al 2014).”
Synchronization of Distant Optical Clocks at the Femtosecond Level
Deschênes, J.-D., Sinclair, L. C., Giorgetta, F. R., Swann, W. C., Baumann, E., Bergeron, H., Cermak, M., Coddington, I., & Newbury, N. R. (2016) · Physical Review X · doi:10.1103/physrevx.6.021016 · Cited by 164
“[8] D.”
Chip-based laser with 1-hertz integrated linewidth
Guo, J., McLemore, C. A., Xiang, C., Lee, D., Wu, L., Jin, W., Kelleher, M., Jin, N., Mason, D., Chang, L., et al. (2022) · Science Advances · doi:10.1126/sciadv.abp9006 · Cited by 112
Metadata
- Authors
- Leibrandt, D. R., Thorpe, M. J., Notcutt, M., Drullinger, R. E., Rosenband, T., & Bergquist, J. C.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2011-02-08
- Volume
- 19
- Issue
- 4
- Pages
- 3471
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W1973817794
- Cited by
- 116
- References
- 3
- FWCI
- 5.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.