The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
In vivo three-dimensional optical coherence elastography
Open accessAbstract
We present the first three-dimensional (3D) data sets recorded using optical coherence elastography (OCE). Uni-axial strain rate was measured on human skin in vivo using a spectral-domain optical coherence tomography (OCT) system providing >450 times higher line rate than previously reported for in vivo OCE imaging. Mechanical excitation was applied at a frequency of 125 Hz using a ring actuator sample arm with, for the first time in OCE measurements, a controlled static preload. We performed 3D-OCE, processed in 2D and displayed in 3D, on normal and hydrated skin and observed a more elastic response of the stratum corneum in the hydrated case.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Biomechanical Properties of In Vivo Human Skin From Dynamic Optical Coherence Elastography
Liang, X., & Boppart, S. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2033464 · Cited by 470
Self-citation
Cited by
A Review of Optical Coherence Elastography: Fundamentals, Techniques and Prospects
Kennedy, B. F., Kennedy, K. M., & Sampson, D. D. (2014) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2013.2291445 · Cited by 334
Self-citationLi, C., Guan, G., Reif, R., Huang, Z., & Wang, R. K. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0583 · Cited by 300
Optical coherence elastography for tissue characterization: a review
Wang, S., & Larin, K. V. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201400108 · Cited by 270
Kennedy, K. M., Chin, L., McLaughlin, R. A., Latham, B., Saunders, C. M., Sampson, D. D., & Kennedy, B. F. (2015) · Scientific Reports · doi:10.1038/srep15538 · Cited by 261
Self-citationElastography imaging: the 30 year perspective
Ormachea, J., & Parker, K. J. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abca00 · Cited by 104
Metadata
- Authors
- Kennedy, B. F., Liang, X., Adie, S. G., Gerstmann, D. K., Quirk, B. C., Boppart, S. A., & Sampson, D. D.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2011-03-23
- Volume
- 19
- Issue
- 7
- Pages
- 6623
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2064129579
- Cited by
- 169
- References
- 2
- FWCI
- 11.30
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo three-dimensional optical coherence elastography. https://app.cochat.ai/papers/10.1364/oe.19.006623
- The paper
- Kennedy, B. F., Liang, X., Adie, S. G., Gerstmann, D. K., Quirk, B. C., Boppart, S. A., & Sampson, D. D. (2011). In vivo three-dimensional optical coherence elastography. Optics Express. https://doi.org/10.1364/oe.19.006623
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.