The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Ultrahigh 22 nm resolution coherent diffractive imaging using a desktop 13 nm high harmonic source
Open accessAbstract
New diffractive imaging techniques using coherent x-ray beams have made possible nanometer-scale resolution imaging by replacing the optics in a microscope with an iterative phase retrieval algorithm. However, to date very high resolution imaging (< 40 nm) was limited to large-scale synchrotron facilities. Here, we present a significant advance in image resolution and capabilities for desktop soft x-ray microscopes that will enable widespread applications in nanoscience and nanotechnology. Using 13 nm high harmonic beams, we demonstrate a record 22 nm spatial resolution for any tabletop x-ray microscope. Finally, we show that unique information about the sample can be obtained by extracting 3-D information at very high numerical apertures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wagner, C., & Harned, N. (2010) · Nature Photonics · doi:10.1038/nphoton.2009.251 · Cited by 650
Cited by
Bright Coherent Ultrahigh Harmonics in the keV X-ray Regime from Mid-Infrared Femtosecond Lasers
Popmintchev, T., Chen, M.-C., Popmintchev, D., Arpin, P., Brown, S., Ališauskas, S., Andriukaitis, G., Balčiunas, T., Mücke, O. D., Pugzlys, A., et al. (2012) · Science · doi:10.1126/science.1218497 · Cited by 1,830
Self-citationPhase Retrieval with Application to Optical Imaging: A contemporary overview
Shechtman, Y., Eldar, Y. C., Cohen, O., Chapman, H. N., Miao, J., & Segev, M. (2015) · IEEE Signal Processing Magazine · doi:10.1109/msp.2014.2352673 · Cited by 1,131
Self-citationBeyond crystallography: Diffractive imaging using coherent x-ray light sources
Miao, J., Ishikawa, T., Robinson, I. K., & Murnane, M. M. (2015) · Science · doi:10.1126/science.aaa1394 · Cited by 808
Self-citationSpin angular momentum and tunable polarization in high-harmonic generation
Fleischer, A., Kfir, O., Diskin, T., Sidorenko, P., & Cohen, O. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.108 · Cited by 612
Generation of bright phase-matched circularly-polarized extreme ultraviolet high harmonics
Kfir, O., Grychtol, P., Turgut, E., Knut, R., Zusin, D., Popmintchev, D., Popmintchev, T., Nembach, H., Shaw, J. M., Fleischer, A., et al. (2015) · Nature Photonics · doi:10.1038/nphoton.2014.293 · Cited by 527
Self-citation
Metadata
- Authors
- Seaberg, M. D., Adams, D. E., Townsend, E. L., Raymondson, D. A., Schlotter, W. F., Liu, Y., Menoni, C. S., Rong, L., Chen, C.-C., Miao, J., Kapteyn, H. C., & Murnane, M. M.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2011-10-25
- Volume
- 19
- Issue
- 23
- Pages
- 22470
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2017808912
- Cited by
- 159
- References
- 1
- FWCI
- 18.51
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrahigh 22 nm resolution coherent diffractive imaging using a desktop 13 nm high harmonic source. https://app.cochat.ai/papers/10.1364/oe.19.022470
- The paper
- Seaberg, M. D., Adams, D. E., Townsend, E. L., Raymondson, D. A., Schlotter, W. F., Liu, Y., Menoni, C. S., Rong, L., Chen, C.-C., Miao, J., Kapteyn, H. C., & Murnane, M. M. (2011). Ultrahigh 22 nm resolution coherent diffractive imaging using a desktop 13 nm high harmonic source. Optics Express. https://doi.org/10.1364/oe.19.022470
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.