Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 260

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Time-resolved protein nanocrystallography using an X-ray free-electron laser

Open access
Aquila, Andrew, Hunter, Mark S., Doak, R. Bruce, Kirian, Richard A., Fromme, Petra, White, Thomas A., Andreasson, Jakob, Arnlund, David, Bajt, Saša, Barends, Thomas R. M., Barthelmess, Miriam, Bogan, Michael J., Bostedt, Christoph, Bottin, Hervé, Bozek, John D., Caleman, Carl, Coppola, Nicola, Davidsson, Jan, DePonte, Daniel P., Elser, Veit, Epp, Sascha W., Erk, Benjamin, Fleckenstein, Holger, Foucar, Lutz, Frank, Matthias, Fromme, Raimund, Graafsma, Heinz, Grotjohann, Ingo, Gumprecht, Lars, Hajdu, Janos, Hampton, Christina Y., Hartmann, Andreas, Hartmann, Robert, Hau-Riege, Stefan, Hauser, Günter, Hirsemann, Helmut, Holl, Peter, Holton, James M., Hömke, André, Johansson, Linda, Kimmel, Nils, Kassemeyer, Stephan, Krasniqi, Faton, Kühnel, Kai-Uwe, Liang, Mengning, Lomb, Lukas, Malmerberg, Erik, Marchesini, Stefano, Martin, Andrew V., Maia, Filipe R.N.C., Messerschmidt, Marc, Nass, Karol, Reich, Christian, Neutze, Richard, Rolles, Daniel, Rudek, Benedikt, Rudenko, Artem, Schlichting, Ilme, Schmidt, Carlo, Schmidt, Kevin E., Schulz, Joachim, Seibert, M. Marvin, Shoeman, Robert L., Sierra, Raymond, Soltau, Heike, Starodub, Dmitri, Stellato, Francesco, Stern, Stephan, Strüder, Lothar, Timneanu, Nicusor, Ullrich, Joachim, Wang, Xiaoyu, Williams, Garth J., Weidenspointner, Georg, Weierstall, Uwe, Wunderer, Cornelia, Barty, Anton, Spence, John C. H., Chapman, Henry N. · 2012 · Optics Express

Abstract

We demonstrate the use of an X-ray free electron laser synchronized with an optical pump laser to obtain X-ray diffraction snapshots from the photoactivated states of large membrane protein complexes in the form of nanocrystals flowing in a liquid jet. Light-induced changes of Photosystem I-Ferredoxin co-crystals were observed at time delays of 5 to 10 µs after excitation. The result correlates with the microsecond kinetics of electron transfer from Photosystem I to ferredoxin. The undocking process that follows the electron transfer leads to large rearrangements in the crystals that will terminally lead to the disintegration of the crystals. We describe the experimental setup and obtain the first time-resolved femtosecond serial X-ray crystallography results from an irreversible photo-chemical reaction at the Linac Coherent Light Source. This technique opens the door to time-resolved structural studies of reaction dynamics in biological systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/oe.20.002706

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 260

Metadata

Authors
Aquila, A., Hunter, M. S., Doak, R. B., Kirian, R. A., Fromme, P., White, T. A., Andreasson, J., Arnlund, D., Bajt, S., Barends, T. R. M., Barthelmess, M., Bogan, M. J., Bostedt, C., Bottin, H., Bozek, J. D., Caleman, C., Coppola, N., Davidsson, J., DePonte, D. P., Elser, V., Epp, S. W., Erk, B., Fleckenstein, H., Foucar, L., Frank, M., Fromme, R., Graafsma, H., Grotjohann, I., Gumprecht, L., Hajdu, J., Hampton, C. Y., Hartmann, A., Hartmann, R., Hau-Riege, S., Hauser, G., Hirsemann, H., Holl, P., Holton, J. M., Hömke, A., Johansson, L., Kimmel, N., Kassemeyer, S., Krasniqi, F., Kühnel, K.-U., Liang, M., Lomb, L., Malmerberg, E., Marchesini, S., Martin, A. V., Maia, F. R. N. C., Messerschmidt, M., Nass, K., Reich, C., Neutze, R., Rolles, D., Rudek, B., Rudenko, A., Schlichting, I., Schmidt, C., Schmidt, K. E., Schulz, J., Seibert, M. M., Shoeman, R. L., Sierra, R., Soltau, H., Starodub, D., Stellato, F., Stern, S., Strüder, L., Timneanu, N., Ullrich, J., Wang, X., Williams, G. J., Weidenspointner, G., Weierstall, U., Wunderer, C., Barty, A., Spence, J. C. H., & Chapman, H. N.
Venue
Optics Express
Published
2012-01-23
Volume
20
Issue
3
Pages
2706
ISSN
1094-4087 (ISSN-L)
OpenAlex
W1968901187
Cited by
260
References
20
FWCI
29.71
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Time-resolved protein nanocrystallography using an X-ray free-electron laser. https://app.cochat.ai/papers/10.1364/oe.20.002706
The paper
Aquila, A., Hunter, M. S., Doak, R. B., Kirian, R. A., Fromme, P., White, T. A., Andreasson, J., Arnlund, D., Bajt, S., Barends, T. R. M., Barthelmess, M., Bogan, M. J., Bostedt, C., Bottin, H., Bozek, J. D., Caleman, C., Coppola, N., Davidsson, J., DePonte, D. P., . . . Chapman, H. N. (2012). Time-resolved protein nanocrystallography using an X-ray free-electron laser. Optics Express. https://doi.org/10.1364/oe.20.002706

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.