The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Maskless imaging of dense samples using pixel super-resolution based multi-height lensfree on-chip microscopy
Open accessAbstract
Lensfree in-line holographic microscopy offers sub-micron resolution over a large field-of-view (e.g., ~24 mm2) with a cost-effective and compact design suitable for field use. However, it is limited to relatively low-density samples. To mitigate this limitation, we demonstrate an on-chip imaging approach based on pixel super-resolution and phase recovery, which iterates among multiple lensfree intensity measurements, each having a slightly different sample-to-sensor distance. By digitally aligning and registering these lensfree intensity measurements, phase and amplitude images of dense and connected specimens can be iteratively reconstructed over a large field-of-view of ~24 mm2 without the use of any spatial masks. We demonstrate the success of this multi-height in-line holographic approach by imaging dense Papanicolaou smears (i.e., Pap smears) and blood samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mobile Phone Based Clinical Microscopy for Global Health Applications
Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006320 · Cited by 694
Cited by
Phase recovery and holographic image reconstruction using deep learning in neural networks
Rivenson, Y., Zhang, Y., Günaydın, H., Teng, D., & Ozcan, A. (2017) · Light: Science & Applications · doi:10.1038/lsa.2017.141 · Cited by 1,059
Self-citationTransport of intensity equation: a tutorial
Zuo, C., Li, J., Sun, J., Fan, Y., Zhang, J., Lu, L., Zhang, R., Wang, B., Huang, L., & Chen, Q. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106187 · Cited by 581
Rivenson, Y., Liu, T., Wei, Z., Zhang, Y., de Haan, K., & Ozcan, A. (2019) · Light: Science & Applications · doi:10.1038/s41377-019-0129-y · Cited by 392
Self-citationOptical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc40864c · Cited by 364
Self-citationOzcan, A., & McLeod, E. (2016) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-092515-010849 · Cited by 352
Self-citationWu, Y., Rivenson, Y., Zhang, Y., Wei, Z., Günaydin, H., Lin, X., & Ozcan, A. (2018) · Optica · doi:10.1364/optica.5.000704 · Cited by 327
Self-citationWide-field computational imaging of pathology slides using lens-free on-chip microscopy
Greenbaum, A., Zhang, Y., Feizi, A., Chung, P.-L., Luo, W., Kandukuri, S. R., & Ozcan, A. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3009850 · Cited by 294
Self-citationQuantitative phase imaging based on holography: trends and new perspectives
Huang, Z., & Cao, L. (2024) · Light: Science & Applications · doi:10.1038/s41377-024-01453-x · Cited by 277
Wu, Y., & Ozcan, A. (2018) · Methods · doi:10.1016/j.ymeth.2017.08.013 · Cited by 260
Self-citationGӧrӧcs, Z., Tamamitsu, M., Bianco, V., Wolf, P., Roy, S., Shindo, K., Yanny, K., Wu, Y., Koydemir, H. C., Rivenson, Y., et al. (2018) · Light: Science & Applications · doi:10.1038/s41377-018-0067-0 · Cited by 188
Metadata
- Authors
- Greenbaum, A., & Ozcan, A.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2012-01-25
- Volume
- 20
- Issue
- 3
- Pages
- 3129
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2026160954
- Cited by
- 225
- References
- 1
- FWCI
- 4.82
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.