Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 484

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Photonic ADC: overcoming the bottleneck of electronic jitter

Open access
Khilo, Anatol, Spector, Steven J., Grein, Matthew E., Nejadmalayeri, Amir H., Holzwarth, Charles W., Sander, Michelle Y., Dahlem, Marcus S., Peng, Michael Y., Geis, Michael W., DiLello, Nicole A., Yoon, Jung U., Motamedi, Ali, Orcutt, Jason S., Wang, Jade P., Sorace-Agaskar, Cheryl M., Popović, Miloš A., Sun, Jie, Zhou, Gui-Rong, Byun, Hyunil, Chen, Jian, Hoyt, Judy L., Smith, Henry I., Ram, Rajeev J., Perrott, Michael, Lyszczarz, Theodore M., Ippen, Erich P., Kärtner, Franz X.·2012·Optics Express

Abstract

Accurate conversion of wideband multi-GHz analog signals into the digital domain has long been a target of analog-to-digital converter (ADC) developers, driven by applications in radar systems, software radio, medical imaging, and communication systems. Aperture jitter has been a major bottleneck on the way towards higher speeds and better accuracy. Photonic ADCs, which perform sampling using ultra-stable optical pulse trains generated by mode-locked lasers, have been investigated for many years as a promising approach to overcome the jitter problem and bring ADC performance to new levels. This work demonstrates that the photonic approach can deliver on its promise by digitizing a 41 GHz signal with 7.0 effective bits using a photonic ADC built from discrete components. This accuracy corresponds to a timing jitter of 15 fs - a 4-5 times improvement over the performance of the best electronic ADCs which exist today. On the way towards an integrated photonic ADC, a silicon photonic chip with core photonic components was fabricated and used to digitize a 10 GHz signal with 3.5 effective bits. In these experiments, two wavelength channels were implemented, providing the overall sampling rate of 2.1 GSa/s. To show that photonic ADCs with larger channel counts are possible, a dual 20-channel silicon filter bank has been demonstrated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/oe.20.004454

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 484

Metadata

Authors
Khilo, A., Spector, S. J., Grein, M. E., Nejadmalayeri, A. H., Holzwarth, C. W., Sander, M. Y., Dahlem, M. S., Peng, M. Y., Geis, M. W., DiLello, N. A., Yoon, J. U., Motamedi, A., Orcutt, J. S., Wang, J. P., Sorace-Agaskar, C. M., Popović, M. A., Sun, J., Zhou, G.-R., Byun, H., Chen, J., Hoyt, J. L., Smith, H. I., Ram, R. J., Perrott, M., Lyszczarz, T. M., Ippen, E. P., & Kärtner, F. X.
Venue
Optics Express
Published
2012-02-08
Volume
20
Issue
4
Pages
4454
ISSN
1094-4087 (ISSN-L)
OpenAlex
W1967062849
Cited by
484
References
21
FWCI
21.57
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Photonic ADC: overcoming the bottleneck of electronic jitter. https://app.cochat.ai/papers/10.1364/oe.20.004454
The paper
Khilo, A., Spector, S. J., Grein, M. E., Nejadmalayeri, A. H., Holzwarth, C. W., Sander, M. Y., Dahlem, M. S., Peng, M. Y., Geis, M. W., DiLello, N. A., Yoon, J. U., Motamedi, A., Orcutt, J. S., Wang, J. P., Sorace-Agaskar, C. M., Popović, M. A., Sun, J., Zhou, G.-R., Byun, H., . . . Kärtner, F. X. (2012). Photonic ADC: overcoming the bottleneck of electronic jitter. Optics Express. https://doi.org/10.1364/oe.20.004454

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.