The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Kilometer-range, high resolution depth imaging via 1560 nm wavelength single-photon detection
Open accessAbstract
This paper highlights a significant advance in time-of-flight depth imaging: by using a scanning transceiver which incorporated a free-running, low noise superconducting nanowire single-photon detector, we were able to obtain centimeter resolution depth images of low-signature objects in daylight at stand-off distances of the order of one kilometer at the relatively eye-safe wavelength of 1560 nm. The detector used had an efficiency of 18% at 1 kHz dark count rate, and the overall system jitter was ~100 ps. The depth images were acquired by illuminating the scene with an optical output power level of less than 250 µW average, and using per-pixel dwell times in the millisecond regime.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The HITRAN2016 molecular spectroscopic database
Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., et al. (2017) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2017.06.038 · Cited by 7,721
The HITRAN 2004 molecular spectroscopic database
Rothman, L. S., Jacquemart, D., Barbe, A., Chris Benner, D., Birk, M., Brown, L. R., Carleer, M. R., Chackerian, C., Chance, K., Coudert, L. H., et al. (2005) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2004.10.008 · Cited by 2,545
Single-photon detectors for optical quantum information applications
Hadfield, R. H. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.230 · Cited by 1,726
Self-citationBashkatov, A. N., Genina, E. A., Kochubey, V. I., & Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/004 · Cited by 1,720
Superconducting nanowire single-photon detectors: physics and applications
Natarajan, C. M., Tanner, M. G., & Hadfield, R. H. (2012) · Superconductor Science and Technology · doi:10.1088/0953-2048/25/6/063001 · Cited by 970
Self-citationLaser ranging: a critical review of usual techniques for distance measurement
Bosch, T. (2001) · Optical Engineering · doi:10.1117/1.1330700 · Cited by 854
Full-waveform topographic lidar: State-of-the-art
Mallet, C., & Bretar, F. (2009) · ISPRS Journal of Photogrammetry and Remote Sensing · doi:10.1016/j.isprsjprs.2008.09.007 · Cited by 811
Single-photon generation and detection
Buller, G. S., & Collins, R. J. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/1/012002 · Cited by 268
Self-citationLaser-based distance measurement using picosecond resolution time-correlated single-photon counting
Pellegrini, S., Buller, G. S., Smith, J. M., Wallace, A. M., & Cova, S. (2000) · Measurement Science and Technology · doi:10.1088/0957-0233/11/6/314 · Cited by 200
Self-citationBuller, G., & Wallace, A. (2007) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2007.902850 · Cited by 189
Self-citationDesign and Performance of an InGaAs–InP Single-Photon Avalanche Diode Detector
Pellegrini, S., Warburton, R. E., Tan, L. J. J., Ng, J. S., Krysa, A. B., Groom, K. M., David, J. P. R., Cova, S., Robertson, M. J., & Buller, G. S. (2006) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.2006.871067 · Cited by 152
Self-citationTanner, M. G., Natarajan, C. M., Pottapenjara, V. K., O’Connor, J. A., Warburton, R. J., Hadfield, R. H., Baek, B., Nam, S. W., Dorenbos, S. N., Bermúdez‐Ureña, E., et al. (2010) · Applied Physics Letters · doi:10.1063/1.3428960 · Cited by 112
Self-citationLaser ranging at 1550 nm with 1-GHz sine-wave gated InGaAs/InP APD single-photon detector
Ren, M., Gu, X., Liang, Y., Kong, W., Wu, E., Wu, G., & Zeng, H. (2011) · Optics Express · doi:10.1364/oe.19.013497 · Cited by 107
Namekata, N., Adachi, S., & Inoue, S. (2010) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2010.2042054 · Cited by 80
Geiger-mode APD camera system for single-photon 3D LADAR imaging
Entwistle, M., Itzler, M. A., Chen, J., Owens, M., Patel, K., Jiang, X., Slomkowski, K., & Rangwala, S. (2012) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.921004 · Cited by 45
Cited by
Demonstration of sub-3 ps temporal resolution with a superconducting nanowire single-photon detector
Korzh, B., Zhao, Q.-Y., Allmaras, J. P., Frasca, S., Autry, T. M., Bersin, E. A., Beyer, A. D., Briggs, R. M., Bumble, B., Colangelo, M., et al. (2020) · Nature Photonics · doi:10.1038/s41566-020-0589-x · Cited by 564
Confocal non-line-of-sight imaging based on the light-cone transform
O’Toole, M., Lindell, D. B., & Wetzstein, G. (2018) · Nature · doi:10.1038/nature25489 · Cited by 505
Kirmani, A., Venkatraman, D., Shin, D., Colaço, A., Wong, F. N. C., Shapiro, J. H., & Goyal, V. K. (2014) · Science · doi:10.1126/science.1246775 · Cited by 473
Esmaeil Zadeh, I., Chang, J., Los, J. W. N., Gyger, S., Elshaari, A. W., Steinhauer, S., Dorenbos, S. N., & Zwiller, V. (2021) · Applied Physics Letters · doi:10.1063/5.0045990 · Cited by 331
Self-citationSuperconducting nanowire single-photon detectors for quantum information
You, L. (2020) · Nanophotonics · doi:10.1515/nanoph-2020-0186 · Cited by 257
Metadata
- Authors
- McCarthy, A., Krichel, N. J., Gemmell, N. R., Ren, X., Tanner, M. G., Dorenbos, S. N., Zwiller, V., Hadfield, R. H., & Buller, G. S.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2013-04-04
- Volume
- 21
- Issue
- 7
- Pages
- 8904
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W1972185094
- Cited by
- 301
- References
- 15
- FWCI
- 21.40
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.