Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 564

The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.

Demonstration of sub-3 ps temporal resolution with a superconducting nanowire single-photon detector

Open access
Korzh, Boris, Zhao, Qing-Yuan, Allmaras, Jason P., Frasca, Simone, Autry, Travis M., Bersin, Eric A., Beyer, Andrew D., Briggs, Ryan M., Bumble, Bruce, Colangelo, Marco, Crouch, Garrison M., Dane, Andrew E., Gerrits, Thomas, Lita, Adriana E., Marsili, Francesco, Moody, Galan, Peña, Cristián, Ramirez, Edward, Rezac, Jake D., Sinclair, Neil, Stevens, Martin J., Velasco, Angel E., Verma, Varun B., Wollman, Emma E., Xie, Si, Zhu, Di, Hale, Paul D., Spiropulu, Maria, Silverman, Kevin L., Mirin, Richard P., Nam, Sae Woo, Kozorezov, Alexander G., Shaw, Matthew D., Berggren, Karl K.·2020·Nature Photonics

Abstract

Improvements in temporal resolution of single-photon detectors enable increased data rates and transmission distances for both classical and quantum optical communication systems, higher spatial resolution in laser ranging, and observation of shorter-lived fluorophores in biomedical imaging. In recent years, superconducting nanowire single-photon detectors (SNSPDs) have emerged as the most efficient time-resolving single-photon-counting detectors available in the near-infrared, but understanding of the fundamental limits of timing resolution in these devices has been limited due to a lack of investigations into the timescales involved in the detection process. We introduce an experimental technique to probe the detection latency in SNSPDs and show that the key to achieving low timing jitter is the use of materials with low latency. By using a specialized niobium nitride SNSPD we demonstrate that the system temporal resolution can be as good as 2.6 ± 0.2 ps for visible wavelengths and 4.3 ± 0.2 ps at 1,550 nm. Knowledge about detection latency provides a guideline to reduce the timing jitter of niobium nitride superconducting nanowire single-photon detectors. A timing jitter of 2.6 ps at visible wavelength and 4.3 ps at 1,550 nm is achieved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41566-020-0589-x

Cites

64 of 64 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 64 references

Cited by

See all 564

Metadata

Authors
Korzh, B., Zhao, Q.-Y., Allmaras, J. P., Frasca, S., Autry, T. M., Bersin, E. A., Beyer, A. D., Briggs, R. M., Bumble, B., Colangelo, M., Crouch, G. M., Dane, A. E., Gerrits, T., Lita, A. E., Marsili, F., Moody, G., Peña, C., Ramirez, E., Rezac, J. D., Sinclair, N., Stevens, M. J., Velasco, A. E., Verma, V. B., Wollman, E. E., Xie, S., Zhu, D., Hale, P. D., Spiropulu, M., Silverman, K. L., Mirin, R. P., Nam, S. W., Kozorezov, A. G., Shaw, M. D., & Berggren, K. K.
Venue
Nature Photonics
Published
2020-03-02
Volume
14
Issue
4
Pages
250-255
ISSN
  • 1749-4885 (ISSN-L)
  • 1749-4893
OpenAlex
W3010109933
Cited by
564
References
64
FWCI
33.17
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Demonstration of sub-3 ps temporal resolution with a superconducting nanowire single-photon detector. https://app.cochat.ai/papers/10.1038/s41566-020-0589-x
The paper
Korzh, B., Zhao, Q.-Y., Allmaras, J. P., Frasca, S., Autry, T. M., Bersin, E. A., Beyer, A. D., Briggs, R. M., Bumble, B., Colangelo, M., Crouch, G. M., Dane, A. E., Gerrits, T., Lita, A. E., Marsili, F., Moody, G., Peña, C., Ramirez, E., Rezac, J. D., . . . Berggren, K. K. (2020). Demonstration of sub-3 ps temporal resolution with a superconducting nanowire single-photon detector. Nature Photonics. https://doi.org/10.1038/s41566-020-0589-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.