Optical coherence tomography system mass-producible on a silicon photonic chip
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Miniaturized integrated optical coherence tomography (OCT) systems have the potential to unlock a wide range of both medical and industrial applications. This applies in particular to multi-channel OCT schemes, where scalability and low cost per channel are important, to endoscopic implementations with stringent size demands, and to mechanically robust units for industrial applications. We demonstrate that fully integrated OCT systems can be realized using the state-of-the-art silicon photonic device portfolio. We present two different implementations integrated on a silicon-on-insulator (SOI) photonic chip, one with an integrated reference path (OCTint) for imaging objects in distances of 5 mm to 10 mm from the chip edge, and another one with an external reference path (OCText) for use with conventional scan heads. Both OCT systems use integrated photodiodes and an external swept-frequency source. In our proof-of-concept experiments, we achieve a sensitivity of -64 dB (-53 dB for OCTint) and a dynamic range of 60 dB (53 dB for OCTint). The viability of the concept is demonstrated by imaging of biological and technical objects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peng, H., Ruan, Z., Long, F., Simpson, J. H., & Myers, E. W. (2010) · Nature Biotechnology · doi:10.1038/nbt.1612 · Cited by 707
Extensible visualization and analysis for multidimensional images using Vaa3D
Peng, H., Bria, A., Zhou, Z., Iannello, G., & Long, F. (2014) · Nature Protocols · doi:10.1038/nprot.2014.011 · Cited by 315
Connecting Silicon Photonic Circuits to Multicore Fibers by Photonic Wire Bonding
Lindenmann, N., Dottermusch, S., Goedecke, M. L., Hoose, T., Billah, M. R., Onanuga, T. P., Hofmann, A., Freude, W., & Koos, C. (2015) · Journal of Lightwave Technology · doi:10.1109/jlt.2014.2373051 · Cited by 159
Self-citation
Cited by
In situ 3D nanoprinting of free-form coupling elements for hybrid photonic integration
Dietrich, P.-I., Blaicher, M., Reuter, I., Billah, M., Hoose, T., Hofmann, A., Caer, C., Dangel, R., Offrein, B., Troppenz, U., et al. (2018) · Nature Photonics · doi:10.1038/s41566-018-0133-4 · Cited by 395
Self-citationOn-chip silicon photonic signaling and processing: a review
Wang, J., & Long, Y. (2018) · Science Bulletin · doi:10.1016/j.scib.2018.05.038 · Cited by 206
Rank, E. A., Sentosa, R., Harper, D. J., Salas, M., Gaugutz, A., Seyringer, D., Nevlacsil, S., Maese-Novo, A., Eggeling, M., Muellner, P., et al. (2021) · Light: Science & Applications · doi:10.1038/s41377-020-00450-0 · Cited by 106
On-chip tunable photonic delay line
Ji, X., Yao, X., Gan, Y., Mohanty, A., Tadayon, M. A., Hendon, C. P., & Lipson, M. (2019) · APL Photonics · doi:10.1063/1.5111164 · Cited by 70
Metadata
- Authors
- Schneider, S., Lauermann, M., Dietrich, P.-I., Weimann, C., Freude, W., & Koos, C.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2016-01-20
- Volume
- 24
- Issue
- 2
- Pages
- 1573
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2431487258
- Cited by
- 74
- References
- 3
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical coherence tomography system mass-producible on a silicon photonic chip. https://app.cochat.ai/papers/10.1364/oe.24.001573
- The paper
- Schneider, S., Lauermann, M., Dietrich, P.-I., Weimann, C., Freude, W., & Koos, C. (2016). Optical coherence tomography system mass-producible on a silicon photonic chip. Optics Express. https://doi.org/10.1364/oe.24.001573
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.