The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Fabry-Pérot resonator: spectral line shapes, generic and related Airy distributions, linewidths, finesses, and performance at low or frequency-dependent reflectivity
Open accessAbstract
We systematically characterize the Fabry-Pérot resonator. We derive the generic Airy distribution of a Fabry-Pérot resonator, which equals the internal resonance enhancement factor, and show that all related Airy distributions are obtained by simple scaling factors. We analyze the textbook approaches to the Fabry-Pérot resonator and point out various misconceptions. We verify that the sum of the mode profiles of all longitudinal modes is the fundamental physical function that characterizes the Fabry-Pérot resonator and generates the Airy distribution. Consequently, the resonator losses are quantified by the linewidths of the underlying Lorentzian lines and not by the measured Airy linewidth. Therefore, we introduce the Lorentzian finesse which provides the spectral resolution of the Lorentzian lines, whereas the usually considered Airy finesse only quantifies the performance of the Fabry-Pérot resonator as a scanning spectrometer. We also point out that the concepts of linewidth and finesse of the Airy distribution of a Fabry-Pérot resonator break down at low reflectivity. Furthermore, we show that a Fabry-Pérot resonator has no cut-off resonance wavelength. Finally, we investigate the influence of frequency-dependent mirror reflectivities, allowing for the direct calculation of its deformed mode profiles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
XXXI. Investigations in optics, with special reference to the spectroscope
Rayleigh (1879) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786447908639684 · Cited by 766
Spectroscopic Foundations of Lasers: Spontaneous Emission Into a Resonator Mode
Eichhorn, M., & Pollnau, M. (2014) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2014.2361783 · Cited by 27
Self-citation
Cited by
Parriaux, A., Hammani, K., & Millot, G. (2020) · Advances in Optics and Photonics · doi:10.1364/aop.382052 · Cited by 385
Boes, A., Chang, L., Knoerzer, M., Nguyen, T. G., Peters, J. D., Bowers, J. E., & Mitchell, A. (2019) · Optics Express · doi:10.1364/oe.27.023919 · Cited by 65
Interference between independent photonic integrated devices for quantum key distribution
Semenenko, H., Sibson, P., Thompson, M. G., & Erven, C. (2019) · Optics Letters · doi:10.1364/ol.44.000275 · Cited by 30
Metadata
- Authors
- Ismail, N., Kores, C. C., Geskus, D., & Pollnau, M.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2016-07-12
- Volume
- 24
- Issue
- 15
- Pages
- 16366
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2461253794
- Cited by
- 282
- References
- 2
- FWCI
- 8.54
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.