The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
OCT elastography: imaging microscopic deformation and strain of tissue
Open accessAbstract
Optical coherence tomography (OCT) has been applied to the study of the microscopic deformation of biological tissue under compressive stress. We describe the hardware and theory of operation of an OCT elastography system that measures internal displacements as small as a few micrometers by using 2D cross-correlation speckle tracking. Results obtained from gelatin scattering models, pork meat, and intact skin suggest possible medical applications of the technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of discrete implementation of generalized cross correlator
Boucher, R., & Hassab, J. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163623 · Cited by 111
Cited by
Biomechanical Properties of In Vivo Human Skin From Dynamic Optical Coherence Elastography
Liang, X., & Boppart, S. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2033464 · Cited by 470
Elastography imaging: the 30 year perspective
Ormachea, J., & Parker, K. J. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abca00 · Cited by 104
Metadata
- Authors
- Schmitt, J. M.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 1998-09-14
- Volume
- 3
- Issue
- 6
- Pages
- 199
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W1980161674
- Cited by
- 620
- References
- 1
- FWCI
- 1.09
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.