Taper-in-taper fiber structure-based LSPR sensor for alanine aminotransferase detection
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Alanine aminotransferase (ALT), a critical component of human blood, is inextricably associated with liver injury. The current study develops a novel biosensor based on the localized surface plasmon resonance (LSPR) principle for the detection of ALT analytes at concentrations ranging from 0 to 1000 Units per liter (U/L). According to the authors' knowledge, this is the first time an optical fiber structure with a taper-in-taper structure has been developed for biosensing applications. It is fabricated using the three-electrode semi-vacuum taper technique and is characterized using a combiner manufacturing system. Gold nanoparticles (AuNPs), molybdenum disulfide nanoparticles (MoS 2-NPs), and cerium oxide nanoparticles (CeO 2-NPs) are immobilized on the sensing region to improve the sensing performance. Prior to application, these nanoparticles are characterized using a high-resolution transmission electron microscope (HR-TEM) and a UV-Visible spectrophotometer. AuNPs promote the LSPR phenomenon, whereas MoS 2-NPs/CeO 2-NPs contribute to the sensor probe's biocompatibility and stability. Following that, the probe surface was functionalized with glutamate oxidase (GluOx) to improve selectivity. The probe demonstrated an excellent linear relationship with the subsequent assay's ALT concentration. Additionally, the probe's performance characteristics such as reusability, reproducibility, stability, and selectivity are evaluated in order to determine its clinical utility in diagnosing liver injury.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Arya, S. K., Dey, A., & Bhansali, S. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.07.015 · Cited by 118
Cited by
Recent Advancements of LSPR Fiber‐Optic Biosensing: Combination Methods, Structure, and Prospects
Zhang, H., Zhou, X., Li, X., Gong, P., Zhang, Y., & Zhao, Y. (2023) · Biosensors · doi:10.3390/bios13030405 · Cited by 99
“(a) Schematic diagram of taper-in-taper fiber structure [74]; (b) Schematic diagram of four”
BackgroundMethodInfluential
Metadata
- Authors
- Wang, Z., Singh, R., Marques, C., Jha, R., Zhang, B., & Kumar, S.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2021-12-14
- Volume
- 29
- Issue
- 26
- Pages
- 43793
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W4200193190
- Cited by
- 162
- References
- 1
- FWCI
- 9.58
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Taper-in-taper fiber structure-based LSPR sensor for alanine aminotransferase detection. https://app.cochat.ai/papers/10.1364/oe.447202
- The paper
- Wang, Z., Singh, R., Marques, C., Jha, R., Zhang, B., & Kumar, S. (2021). Taper-in-taper fiber structure-based LSPR sensor for alanine aminotransferase detection. Optics Express. https://doi.org/10.1364/oe.447202
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.