Taper-in-taper fiber structure-based LSPR sensor for alanine aminotransferase detection
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Alanine aminotransferase (ALT), a critical component of human blood, is inextricably associated with liver injury. The current study develops a novel biosensor based on the localized surface plasmon resonance (LSPR) principle for the detection of ALT analytes at concentrations ranging from 0 to 1000 Units per liter (U/L). According to the authors' knowledge, this is the first time an optical fiber structure with a taper-in-taper structure has been developed for biosensing applications. It is fabricated using the three-electrode semi-vacuum taper technique and is characterized using a combiner manufacturing system. Gold nanoparticles (AuNPs), molybdenum disulfide nanoparticles (MoS 2-NPs), and cerium oxide nanoparticles (CeO 2-NPs) are immobilized on the sensing region to improve the sensing performance. Prior to application, these nanoparticles are characterized using a high-resolution transmission electron microscope (HR-TEM) and a UV-Visible spectrophotometer. AuNPs promote the LSPR phenomenon, whereas MoS 2-NPs/CeO 2-NPs contribute to the sensor probe's biocompatibility and stability. Following that, the probe surface was functionalized with glutamate oxidase (GluOx) to improve selectivity. The probe demonstrated an excellent linear relationship with the subsequent assay's ALT concentration. Additionally, the probe's performance characteristics such as reusability, reproducibility, stability, and selectivity are evaluated in order to determine its clinical utility in diagnosing liver injury.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Liver enzyme alteration: a guide for clinicians
Giannini, E. G. (2005) · Canadian Medical Association Journal · doi:10.1503/cmaj.1040752 · Cited by 2,016
Shukla, R., Bansal, V., Chaudhary, M., Basu, A., Bhonde, R. R., & Sastry, M. (2005) · Langmuir · doi:10.1021/la0513712 · Cited by 1,687
A review of fiber-optic biosensors
Leung, A., Shankar, P. M., & Mutharasan, R. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2007.03.010 · Cited by 693
Pieper, J. S., Hafmans, T., Veerkamp, J. H., & van Kuppevelt, T. H. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00222-7 · Cited by 323
Alanine Aminotransferase-Old Biomarker and New Concept: A Review
Liu, Z., Que, S., Xu, J., & Peng, T. (2014) · International Journal of Medical Sciences · doi:10.7150/ijms.8951 · Cited by 266
Kaushik, S., Tiwari, U. K., Pal, S. S., & Sinha, R. K. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.11.006 · Cited by 212
2D material assisted SMF-MCF-MMF-SMF based LSPR sensor for creatinine detection
Li, M., Singh, R., Marques, C., Zhang, B., & Kumar, S. (2021) · Optics Express · doi:10.1364/oe.445555 · Cited by 176
Self-citationAlanine aminotransferase in clinical practice. A review
Sherman, K. E. (1991) · Archives of Internal Medicine · doi:10.1001/archinte.151.2.260 · Cited by 173
Liangpunsakul, S., & Chalasani, N. (2005) · The American Journal of the Medical Sciences · doi:10.1097/00000441-200503000-00001 · Cited by 170
Pyridoxal phosphate-dependent reactions in the biosynthesis of natural products
Du, Y.-L., & Ryan, K. S. (2019) · Natural Product Reports · doi:10.1039/c8np00049b · Cited by 143
Arya, S. K., Dey, A., & Bhansali, S. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.07.015 · Cited by 118
Kunutsor, S. K., Apekey, T. A., Hemelrijck, M. V., Calori, G., & Perseghin, G. (2014) · International Journal of Cancer · doi:10.1002/ijc.29084 · Cited by 111
LSPR-based cholesterol biosensor using a tapered optical fiber structure
Kumar, S., Kaushik, B. K., Singh, R., Chen, N., Yang, Q., Zhang, X., Wang, W., & Zhang, B. (2019) · Biomedical Optics Express · doi:10.1364/boe.10.002150 · Cited by 111
Self-citationSeo, S. I. (2015) · World Journal of Gastroenterology · doi:10.3748/wjg.v21.i13.3928 · Cited by 106
Sharma, J. N., Pattadar, D. K., Mainali, B. P., & Zamborini, F. P. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01905 · Cited by 104
Tapered Optical Fiber-Based LSPR Biosensor for Ascorbic Acid Detection
Guo, Z., Singh, L., Wang, Y., Singh, R., Zhang, B., Liu, F., Kaushik, B. K., & Kumar, S. (2020) · Photonic Sensors · doi:10.1007/s13320-020-0605-2 · Cited by 73
Self-citationLabel-free tapered optical fiber plasmonic biosensor
Liyanage, T., Lai, M., & Slaughter, G. E. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338629 · Cited by 71
Controlling distance, size and concentration of nanoconjugates for optimized LSPR based biosensors
Chowdhury, A. D., Nasrin, F., Gangopadhyay, R., Ganganboina, A. B., Takemura, K., Kozaki, I., Honda, H., Hara, T., Abe, F., Park, S., et al. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112657 · Cited by 65
Ansar, S. M., Chakraborty, S., & Kitchens, C. L. (2018) · Nanomaterials · doi:10.3390/nano8050339 · Cited by 64
Advances in biosynthesis of noble metal nanoparticles mediated by photosynthetic organisms—A review
Bao, Z., & Lan, C. Q. (2019) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2019.110519 · Cited by 60
A stable and selective electrochemical biosensor for the liver enzyme alanine aminotransferase (ALT)
Jamal, M., Worsfold, O., McCormac∥, T., & Dempsey, E. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.02.032 · Cited by 54
Song, T., Fu, L., Wan, N., Wu, J., & Xie, J. (2020) · Journal of CO2 Utilization · doi:10.1016/j.jcou.2020.101231 · Cited by 48
Azmi, N. E., Rashid, A. H. A., Abdullah, J., Yusof, N. A., & Sidek, H. (2018) · Journal of Luminescence · doi:10.1016/j.jlumin.2018.05.075 · Cited by 48
Lee, S. M., Park, J. S., Han, Y. J., Kim, W. K., Bang, S. H., Kim, B. J., Park, C., & Kim, M. Y. (2020) · Journal of Korean Medical Science · doi:10.3346/jkms.2020.35.e198 · Cited by 46
Li, K., Wu, W., Jiang, Y., Wang, Z., Liu, X., Li, J., Xia, D., Xu, X., Fan, J., & Lin, K. (2020) · Inorganic Chemistry Frontiers · doi:10.1039/d0qi01222j · Cited by 45
Self-citationMyoglobin immobilized on LaF3 doped CeO2 and ionic liquid composite film for nitrite biosensor
Dong, S., Li, N., Huang, T., Tang, H., & Zheng, J. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.07.073 · Cited by 27
3D MoS2-AuNPs carbon paper probe for ultrasensitive detection and discrimination of p53 gene
Zhao, J., Huo, D., Geng, X., Bao, J., Hou, J., Shui, Z., Yang, H., Qi, Y., Hu, Y., Yang, M. J., et al. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.129480 · Cited by 22
Dey, J., Hazra, B., & Chandra, M. (2019) · The Journal of Chemical Physics · doi:10.1063/1.5116528 · Cited by 8
Cited by
Recent Advancements of LSPR Fiber‐Optic Biosensing: Combination Methods, Structure, and Prospects
Zhang, H., Zhou, X., Li, X., Gong, P., Zhang, Y., & Zhao, Y. (2023) · Biosensors · doi:10.3390/bios13030405 · Cited by 99
“(a) Schematic diagram of taper-in-taper fiber structure [74]; (b) Schematic diagram of four”
BackgroundMethodInfluential
Metadata
- Authors
- Wang, Z., Singh, R., Marques, C., Jha, R., Zhang, B., & Kumar, S.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2021-12-14
- Volume
- 29
- Issue
- 26
- Pages
- 43793
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W4200193190
- Cited by
- 162
- References
- 28
- FWCI
- 9.58
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.