The DOI matches its Crossref record.
Improvement in retinal image quality with dynamic correction of the eye’s aberrations
Open accessAbstract
We measured the improvement in retinal image quality provided by correcting the temporal variation in the eye's wave aberration with a closed-loop adaptive optics system. This system samples the eye's wave aberration at rates up to 30 Hz. Correction of the eye's aberrations can be completed in 0.25-0.5 seconds, resulting in residual rms wave-front errors as low as 0.1 microns for 6.8 mm pupils. Real-time wave-front measurements were used to determine how effectively the spatial and temporal components of the eye's wave aberration were corrected. The system provides dynamic correction of fluctuations in Zernike modes up to 5 th order with temporal frequency components up to 0.8 Hz. Temporal performance is in good agreement with predictions based on theory. Correction of the temporal variation in the eye's wave aberration increases the Strehl ratio of the point spread function nearly 3 times, and increases the contrast of images of cone photoreceptors by 33% compared with images taken with only static correction of the eye's higher order aberrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Organization of the human trichromatic cone mosaic
Hofer, H., Carroll, J., Neitz, J., Neitz, M., & Williams, D. R. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.2414-05.2005 · Cited by 364
Self-citationNeural compensation for the eye’s optical aberrations
Artal, P., Chen, L., Fernández, E. J., Singer, B., Manzanera, S., & Williams, D. R. (2004) · Journal of Vision · doi:10.1167/4.4.4 · Cited by 332
Self-citationHanda, J. T., Bowes Rickman, C., Dick, A. D., Gorin, M. B., Miller, J. W., Toth, C. A., Ueffing, M., Zarbin, M., & Farrer, L. A. (2019) · Nature Communications · doi:10.1038/s41467-019-11262-1 · Cited by 282
Functional photoreceptor loss revealed with adaptive optics: An alternate cause of color blindness
Carroll, J., Neitz, M., Hofer, H., Neitz, J., & Williams, D. R. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0401440101 · Cited by 191
Self-citation
Metadata
- Authors
- Hofer, H., Chen, L., Yoon, G. Y., Singer, B., Yamauchi, Y., & Williams, D. R.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2001-05-21
- Volume
- 8
- Issue
- 11
- Pages
- 631
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W1985596818
- Cited by
- 246
- References
- 0
- FWCI
- 8.25
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improvement in retinal image quality with dynamic correction of the eye’s aberrations. https://app.cochat.ai/papers/10.1364/oe.8.000631
- The paper
- Hofer, H., Chen, L., Yoon, G. Y., Singer, B., Yamauchi, Y., & Williams, D. R. (2001). Improvement in retinal image quality with dynamic correction of the eye’s aberrations. Optics Express. https://doi.org/10.1364/oe.8.000631
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.